PROBLEM CAUSE SOLUTION
1. The boiler is full of water and
the water flows out of the
safety valve.
• One of the out ow lines from the
boiler or from a circuit of
the unit
has a leak.
• Check the autolevel circuit, the manual charging
button, and the boiler
heat exchangers.
Replace worn or damaged parts to eliminate
the leak.
2. The safety valve trips in
and vents the steam.
Malfunction of electrical system
(the electrical heating element
is always connected).
Pressure increase in the boiler
(the safety valve trips in at 1.9-
2.5 bar).
Check the wiring that feeds the heat-ing ele-
ment and the pressure switch.
In the machines with electronic tem perature
control, check the proper operation of the elec-
tronic control unit, the triac, the level probe, and
the elettrical wiring
.
3. The machine was started prop-
erly but the water in the boiler
does not warm up.
The electric heating element is
defective or is not connected.
Check if the heating element is con-nected to
the power supply.
Check if the heating element safety thermostat
has tripped in and check its proper operation.
In the machines with electronic tem perature
control, check the proper operation of the elec-
tronic control unit, the triac, the level probe, and
the elettrical wiring
4. There is no water owing from
a serving unit.
Coffee ground too fine or ex-
cessive quantity for type of lter
used.
Clogged water circuit.
• Defective solenoid.
• Adjust the grinding coarseness and/or the quan-
tity of ground coffee.
Check that the injector, the upper cir culation
tube, the spray nozzle and the solenoid of the
unit are not clogged.
In the machines with electronic metering, check
the displacement meter and its valves.
Check the solenoid of the unit, its wiring and
the fuse in the electronic control unit.
5. The programmed servings of
espresso coffee are not con-
stant or vary on the dif- ferent
units.
Abnormal operation of the elec-
tronic control unit or of the dis-
placement counters.
Leak from serving unit solenoid
valve.
Program the serving quantities sepa rately on
each serving unit. If the problem persists, re-
place the dis placement meter of the serving
unit affected.
Replace the solenoid valve of the serving
unit.
6. It is not possible to pro- gram
the serving quantities on unit 1
and to copy them on the other
units.
Abnormal operation or defective
displacement meter of unit 1.
Check the control unit-displacement meters
electrical wiring.
Replace the displacement meter.
7. Displacement meters alarm. Displacement meters jammed
or defective.
• Defective wiring.
Replace the displacement meter.
Check the wiring and its connections, the con-
trol unit and the fuses.
8. Autolevel alarm. Lack of water in the autolevel
circuit.
Main water supply valve
closed.
Faulty autolevel solenoid.
Check the hydraulic circuit of the autolevel.
Check if the on-off valve on the water supply
is open.
Replace the autolevel solenoid.
9. The machine is switched on
(the main switch is in position
1 or 2 and the signal light is lit)
but the electronic control is out
of order.
The electric wiring of the elec-
tronic control unit is defective.
The electronic control unit is
defective.
Check the electrical wiring, the elec tronic con-
trol unit and its components.