START UP PROCEDURES
Follow recommendations for site location
and electrical connection. The water line on
the weir door is the level at which the water
should be maintained.
1. Fill the spa through the  lter hole to
1/8” below the top of the Weir door. with
tap water. Never use softened’ water in
your spa. Softened water can impact the
chemical balance of the water and lead to
degradation of metal plumbing  ttings.
2. Turn power on to unit at circuit breaker or
disconnect panel.
3. Open the air controls, located on the top
lip, and cycle the jets from high to low.
Water should come from the therapy jets.
If water  ow is not established, turn o jets
and see Priming Your Spa (this page).
4. Add chemicals. Ask your dealer for
additional information.on start up or
getting the water balanced.
Follow Operating Instructions for your
particular model to set heat to the desired
temperature. Initially, you may  nd that
the spa requires 12 to 14 hours on 230 Volt
installations to reach temperature. Keep your
thermal cover on the unit and close the air
controls to help the heating process.
NOTE: At the start of a  ltration cycle, the
Air System is activated to purge the lines
and ensure complete  ltration. If you have
the air system nsure that at least one air
control is always fully open.
Priming Your Spa
When  lling your spa for the  rst time or,
after draining and re lling the spa, you
may need to bleed air from the system.
Should you experience an air-lock on
Pump 1, remove the  lter cover,
insert a garden hose through each center
hole that holds the  lter as far as possible
without using force. Hold the hose in place
and turn on the water. Cycle pump 1 from
low to high several times, this forces water
into the pump and forces the air out. If this
does not work or you experience an air-lock
on Pump 2, remove the side panel and
locate the pump. With the pump on high
speed, slowly loosen the discharge (top)
pump union until water starts to trickle out.
Once water is trickling out, hand tighten
the union (do not over tighten as this could
cause the union to crack) and replace the
side panel
Pr - This is Not an Error Message
The Spa has just been powered up and is in
Priming Mode for 4 Minutes. Pumps can be
turned ON and OFF to remove any air from
the plumbing lines and the Heater. Cycle
the pumps on and o to verify good water
ow and wait 4 minutes or press any temp
related button to exit Priming Mode.
Important: Do not operate the spa
without full water  ow.