Owner`s manual
25
VITA SPA
ENGLISHFRANÇAIS
wires and installing the proper grounds. To
take full advantage of the unique capabilities
of your new spa, you should rst set the time
and establish your ltration cycles.
Setting the Time
When the time of day has not been
programmed, the icon will be ashing on
the LCD window. To set the time of day, rst
press the ‘TIME’ button then press the ‘PROG’
button. The hour digit(s) will be ashing on
the LCD window. Press the ‘UP’ or ‘DOWN’
button to advance the hours up or down to
the desired set point. Press the
‘PROG’ button to enter the time hour. The
minute digits will now be ashing on the LCD
window. Press the ‘UP’ or ‘DOWN’ button
to advance the minutes up or down to the
desired set point. Press the ‘PROG’ button to
enter the time minutes. At this point you can
either proceed with setting the ltration cycles
as described in the following ‘Changing Filter
Cycle’ section, or press the ‘TIME’ button to
save the settings and exit the programming
sequence.
Preset Filter Cycles
Once the time of day has been set, your spa
will automatically lter the water for a 2-hour
period every 12 hours.
The rst lter cycle comes preset to operate
from 8:00AM to 10:00AM, and the second
lter cycle comes preset to operate from
8:00PM to 10:00PM. The F1 indicator light
will be lit whenever the spa is in the rst
lter cycle. The F2 indicator light will be lit
whenever the spa is in the second lter cycle.
During a lter cycle, the primary ltration
pump will operate in low speed and can not
be turned o unless the spa is put into the
cycles. The ‘ECN’ icon may be displayed in
the LCD window and the word economy will
be displayed on the panel when this mode
is selected. While in the Economy mode,
pressing the ‘JE TS 1’ button will put the spa
into the Standard-In-Economy mode, which
operates the same as the Standard Mode,
then reverts back to the Economy mode after
1 hour. The spa can be immediately reverted
back into the Economy mode at any time by
simply pressing the ‘PROG’ button.
Sleep Mode heats the spa to within 20°F
(11°C) of the set temperature only during
lter cycles. The ‘SLP’ icon may be displayed
in the LCD window and the word sleep will
be displayed on the panel when this mode is
selected.
Standby Mode: While in this mode, all
spa functions are temporarily suspended
to allow for lter changes or other routine
maintenance tasks.
Changing Modes
To change the operating mode, press the
‘PROG’ button. The operating mode will be
ashing on the LCD window. Press the ‘DOWN’
button to cycle through to the desired mode,
and then press the ‘PROG’ button to con rm
selection. Pressing
Pressing ‘UP’ or ‘DOWN’ then ‘JETS2’ will put the
spa into the Standby Mode. Press any button
to exit the Standby mode.
Time and Filtration Cycles
The control system on your spa has been
designed to function properly and safely at
104F (40°C) after connecting the electrical