The low speed operation of Pump 1 is timed
to automatically turn o after 4 hours of
operation. The high speed operation of Pump 1
and the high speed operation of Pump 2,
are timed to automatically turn o after 15
minutes of operation.
NOTE (NON-Circ Pump Systems): The low
speed of Pump 1 runs when the blower or
any other pump is on. In the STANDARD
mode it will also activate for at least 2
minutes every 30 minutes to detect the
spa water temperature and then remain on
to heat to the set temperature if needed.
When this automatic activation occurs, the
low speed of Pump 1 cannot be turned o ;
however, all other control functions can be
activated.
Light
Touch the LIGHT pad to turn all lights on and
o . The lights will automatically turn o after 4
hours of operation.
Operating Modes
Your Vita Spa comes with three primary
operating modes.
Standard Mode maintains the water at
the desired set temperature. Note that the
last measured spa temperature displayed
is current only when the pump has been
running for at least 2 minutes. The ‘STD’ icon
will be brie y displayed in the LCD window
when this mode is selected.
Economy Mode heats the water to the
desired set temperature ONLY during  lter
cycles. The ‘ECN’ icon will be displayed in
the LCD window when this mode is selected.
Sleep Mode heats the spa to within 20°F
(-6.6°C) of the set temperature only during
lter cycles. The ‘SLP’ icon will be displayed in
the LCD window when this mode is selected.
Changing Modes
To change the operating mode, press the ‘UP
or ‘DOWN’ and the press the ‘PROG’ button.
The operating mode will be  ashing on the
LCD window. Press the ‘DOWN’ button to
cycle through to the desired mode.
Time and Filtration Cycles
The control system on your spa has been
designed to function properly and safely at
100°F (38°C) after connecting the electrical
wires and installing the proper grounds. To
take full advantage of the unique capabilities
of your new spa, you should  rst set the time
and establish your  ltration cycles.
Preset Filter Cycles
The spa control system is designed with two
lter cycles. The  rst lter cycle turns on 6
minutes after power is supplied to the spa. The
second  lter cycle begins 12 hours later. Filter
cycles are pre-set for a two hour duration.
Note: To properly clean and maintain spa,
a total  lter time of at least four hours per
day is recommended. If an ozonator is
installed 6 hours is recommended.
Changing Filter Cycle Start Time
The start/stop times of the  lter cycle begin 6
minutes after the spa set time is established.
Set time is based on the time of day that the
spa is powered up. Set time may only be
changed by disconnecting power from the
spa and reconnecting it at the desired start
time. For example, if you want the  lter cycle
to begin at 9:00 PM, turn o the breaker or
disconnect the spa and reconnect it at 8:54
PM (remember the 6 minute wait period). The
cycle will begin at 9:00 PM and will repeat
beginning at 9:00 AM. Each cycle will run for