Owner`s manual
33
VITA SPA
ENGLISHFRANÇAIS
OPTIONS & FEATURES
CIRCULATION PUMP OR CIRC PUMP
OPTION:
Circulation pump (CIRC PUMP): 504 system
The circ pump will turn on immediately upon
power up; the prime mode (Pr) does not apply
to this feature. All other equipment will turn
on brie y at the beginning of each ltration
cycle to purge the plumbing lines.
If your spa is con gured with the circ pump
option it is designed to run constantly ltering
the water. The circ pump will turn o when
the water temperature is detected to be 3F
above the set temperature to reduce overheat
conditions. During the summer months or
when the ambient air temperatures are above
90F it is important to monitor the water
temperature to identify and manage potential
thermal creep or overheat situations. See
THERMAL CREEP on pg 37
Circulation pump (CIRC PUMP): 460 & 760
systems
The circ pump will turn on once you exit the
the prime mode (Pr). All other equipment
will turn on brie y at the beginning of each
ltration cycle to purge the plumbing lines.
The circ pump operates continuously
(24 hours) with the exception of turning
o for 30 minutes when the water
temperature reaches 3°F (1.5°C) above the
set temperature (most likely to happen in
warm climates). During the summer months
or when the ambient air temperatures are
above 90F it is important to monitor the water
temperature to identify and manage potential
thermal creep or overheat situations. See
THERMAL CREEP on pg 37
The mode settings will now work with circ
pump. When your spa is in the Standard
mode the heater will turn on as needed to
maintain the set temperature. When it is in
the Economy Mode, the heater will only be
activated during the programmed ltration
cycle time and will heat the water to the set
temperature. In the Sleep mode the heater will
only activate if the water temperature is 20°F
(11°C) below the set temperature
Inversion Feature ( 460 & 760 systems )
The Control System includes an Inversion
feature that makes it easy to read the LCD
from inside or outside the spa. To invert the
LCD display, touch the ‘UP’ or ‘DOWN’ button,
followed by the ‘AIR’ button. Repeat the
sequence to reverse the inversion process.
If your spa is not equipped with the optional
AIR feature, locate the position of the AIR
button (next to the LIGHT button) and press in