Owner`s manual
Table Of Contents
- Cover
- Acrobat Viewing Instructions
- Table of Contents
- Table of Contents-Close Up
- Owner's Record-(Print for your records)
- Pg01: President's Message
- Pg02: Important Safety Instructions
- Pg03: Do's and Don'ts
- Pg03:Warnings
- Pg04: Installation Instructions
- Pg05: Clearances
- Pg06: Electrical Requirements& Installation 1
- Pg07: Electrical Requirements& Installation 2
- Pg08: Electrical Requirements& Installation 3
- Pg09: Electrical Requirements& Installation 4
- Pg10: Electrical Requirements& Installation 5
- Pg11: Cover Installation
- Pg12: Operating Instructions
- Pg13: Using Your Spa
- Pg14: Special Features 1
- Pg15: Special Features 2
- Pg16: Advance Features
- Pg17: Jet Operation 1
- Pg18: Jet Operation 2
- Pg19: Jet Operation 3
- Pg20: VitAroma
- Pg21: Water Purification System
- Pg22: Spa Maintenance 1
- Pg23: Spa Maintenance 2
- Pg24: Spa Maintenance 3
- Pg25: Spa Maintenance 4
- Pg26: Water Quality & Maintenance
- Pg27: Important Water Maint. Procedures
- Pg28: Balancing Spa Water 1
- Pg29: Balancing Spa Water 2
- Pg30: Water Maint. Do's & Don'ts
- Pg31: Spa Water Troubleshooting 1
- Pg32: Spa Water Troubleshooting 2
- Pg33: Diagnostic & Troubleshooting
- Pg34: LCD Display Glossary
- Pg35: Maintenance Log (for Printing)
- Mfg Address & Phone Numbers

PAGE 6
W IRE YOUR SPA PER ONE OF THE DI A GRA MS MO ST SIMILAR TO YOUR
HOUSE PA NEL
ALL WIRES FEEDING THE SPA ARE TO BE THE SAME GAUGE. GROUND WIRES ARE
TO BE INSULATED AS WELL. WHEN USING A GROUND ROD, THE GROUND WIRE
TO THE ROD SHOULD BE #6 BARE COPPER.
ALL SPAS REQUIRE THE USE OF AN ISOLATED GFCI PROTECTED CIRCUIT. THE
INSTALLATION OF A DISCONNECT IS REQUIRED NO MORE THAN TEN (10) VISUAL
FEET FROM THE SPA AND NOT LESS THAN FIVE (5) FEET.
THIS REQUIREMENT IS TO ASSURE THAT WHEN POWER IS DISCONNECTED FROM
THE SPA, POWER CAN NOT BE INADVERTENTLY TURNED BACK ON.
EL E C T R ICAL RE QUIREMEN TS AND INSTA L LAT ION
S E PA RATE NE U T RAL & SO L ID
G R O UND