Owner`s manual
PAGE 16
F. FLOW PROTECTION
If the flow of water through the heater is
insufficient, the spa controller will
automatically turn the heater off to
prevent overheating. Self-testing will be
initiated by the diagnostic control. Call for
service if you cannot pinpoint the cause.
G. OVERHEAT PROTECTION
If the water temperature inside the spa
reaches 112 F, the pumps and the heater
will be disabled. If the water temperature
continues to rise and reaches 118 F due
to friction in the pumps and plumbing
system, the entire system including all
pumps will be disabled. In “HILI”
condition, DO NOT ENTER THE WATER.
Remove the cover and allow the water
temperature to cool down to 104 F.
Then, reset the system by holding down
the “PROG” button for 5 seconds while
in time display mode. If the “HILI”
message returns, call for service.
H. DIAGNOSTIC
When in temperature set mode ( Heat
Icon Flashing ), then slowly press the PROG
button three times..
When the screen reads
P=2 or P=1 press the PROG button once
again. If the screen displays something other
than P=2 or P=1, use the up or down arrow
buttons to change the screen to read the
number of pumps in your spa. Then press the
PROG button once mXore. The screen will
now be displaying the level of amperage draw.
S=3 Indicates that the heater will stay on when
the pumps are on at anytime. High or Low
speed.
S=2 Indicates that the heater will shut off if either
of the large pumps are turned on high speed
S=1 Indicates that the heater will only run when
the primary pump is on low speed. Since the
heater is associated with the HEET pump
system, the primary pump does not need to
be on for the heater to operate. Yet in an
effort to control the amperage draw and
conserve electricity, the heater will run if the
primary pump is turned onto low speed but
then shut off while the primary pump goes to
high speed or if the secondary pump is
turned on high. Once the power level has
been set, this does not have to be set each
time. It will be entered into the system
memory.
Press the PROG button once again. The
diagnostic test will commence and run for the
next three and a half minutes. Anytime during
the first minute of testing, you can stop the
test by pressing the PROG button once and
use the VIEW button to cycle through the
programming mode.
Upon completion of the test, if everything is
operating correctly, the message GOOD will
be displayed for 30 seconds.
I. SKIM–AWAY (AVAILABLE ONLY
WITH CIRCULATION PUMP OPTION)
Skim–Away is an automatic skimming
action which takes place each day from
8am until 8:30am each morning and
from 4pm until 4:30pm each afternoon.
The primary and secondary pumps will
activate in low speed mode. This will pull all
surface oils and debris into the filter well
cavity.
ADD START UP CHEMICALS
Carefully follow the directions and add
the start-up chemicals recommended to
you by your dealer. Contact your dealer to
clarify any questions you may have.
Your spa comes ready for the Vita
exclusive “Sparkle Clear” natural
mineral purification cartridges. Combined
with an ozonator, “Sparkle Clear” offers an
alternative to Bromine or other chlorine
sanitizers. Sparkle Clear and ozone will
make your spa look cleaner, smell
cleaner, feel softer and eliminate skin or
eye irritation. Ask your dealer about Vita