Owner`s manual
PAGE 32
DIAGNOSTIC & TROUBLESHOOTING
SYMPTOM
Spa Inoperative
Spa Side Inoperative
M
ESSAGE
BLO
CP
CS
F1
F2
HC
HP
LP
P1
P2
Pb
PS
LS
SS
HILI
M
EANING
Power failure outside of spa.
Spa Side could be locked.
Blower Error
HEET pump may be faulty.
Current Sensor
Blown Fuse
Blown Fuse
Heater Error
High Voltage
Low Voltage
Pump 1 Error
Pump 2 Error
Power Board Communication
Pressure Switch Error
Water Sensor
Heater Sensor
High Limit Sensor Detects
Temperature Rise Above 112F
A
CTION
Check power source Breaker and GFCI;
Reset breaker/GFCI. Call Electrician if it
will not start.
If lock icon is visible, unlock by depressing
the “UP” button for 5 seconds
Check fuse 3 and then verify that the
blower motor is plugged in.
Check that HEET pump is plugged in.
Check that current sensor board is plugged
into circuit board.
Replace fuse 1
Replace fuse 2
Replace heater
High power (voltage) observed. Check
power connections and rerun diagnostic
test
Low Power (voltage) observed. Check
power connections and rerun diagnostic
test
Check plug for Pump 1
Check plug for Pump 2
Check topside connection and remote
panel connections to power board.
Replace Pressure Switch
Replace Sensor
Replace Sensor
Allow Spa to Cool, Power Down Spa, Turn
Power Back on and Reset Spa Side Control
IF ANY ERRORS ARE FOUND, THE FOLLOWING MESSAGES MAY BE DISPLAYED: