IMPORTANT SAFETY INSTRUCTIONS READ ENTIRE MANUAL BEFORE INSTALLING SPA. PLEASE SAVE THIS MANUAL OWNER’S MANUAL for models xStream • xStreamPro • xStreamDuoPro DM INDUSTRIES, LTD. 2320 N.W. 147th Street Miami, Florida 33054 www.dmindustries.
ID PLATES ARE LOCATED IN THE FRONT OF THE SPA. A SMALL ID TAG IS FOUND IN THE BASE OF THE UNIT, AND A COMPLETE ID TAG IS FOUND ONCE THE FRONT PANELS ARE REMOVED. Model Number P817G2DC117ACB Serial Number 09D12345BTZ 09D12345BTZ P817G2DC117ACB C DM Industries, LTD. 2350 N.W. 147 Street Miami, FL 33021 (305) 685-5739 www.dmindustries.com LIST ED US CONFORMS TO ANSI/UL STD 1563 CERTIFIED TO CAN/CSA C22.2 STD NO.218.
OWNER’S MANUAL for models xStream • xStream Pro • xStream Duo Pro OWNER’S RECORD DATE PURCHASED: ________________________________________ DATE INSTALLED: _________________________________________ DEALER: __________________________________________________ ADDRESS: ________________________________________________ ___________________________________________________________ TELEPHONE: ______________________________________________ SERIAL #: _________________________________________________ MODEL #: _________
TABLE OF CONTENTS GENERAL INFORMATION SWIM OPERATION (continued) • Important Safety Instructions . . . . . . . . . . . . . . 1 Swim Programming Instructions . . . . . . . . . . . 13 • Manufacturer’s Do’s and Don’ts . . . . . . . . . . . . 2 • Setting Heat Days & Permanent Temperature 13 • F or C Degrees. . . . . . . . . . . . . . . . . . . . . . . . . 13 SET UP AND INSTALLATION • Filtration Cycle . . . . . . . . . . . . . . . . . . . . . . . . . 13 • Set Up and Installation Instructions. . . . . . .
IMPORTANT SAFETY INSTRUCTIONS WHEN INSTALLING AND USING THIS ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING DANGERS: 1. WARNING - To reduce the risk of injury. Do not permit C. Before entering a spa the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature-regulating devices varies. children to use this product unless they are closely supervised at all times. D.
MANUFACTURER’S DO’S AND DON’TS Reading and understanding these warnings will allow you to reduce the risk of causing inadvertent damage to your spa, your surroundings, or yourself. Read these warnings carefully. DO Make sure the spa is connected to a Ground Fault Circuit Interrupter (GFCI). Test the GFCI before each use. DO Test the water with your hand before entering the spa to be sure it is comfortable. DO Remember that wet surfaces can be slippery. Take care when entering and existing the spa.
WARNING LABEL INSTALLATION Position warning label in visible area prior to entry of spa. For instructions, please refer to posted warnings located on page 1 If replacements are needed please contact local dealer and order using part number: “0461536 - Warning Label” NO DIVING WARNING DO NOT DIVE INTO SPA. IT CAN CAUSE HARM OR INJURY. COVER INSTALLATION INSTALLING THE SPA COVER Cover 1. Position the cover squarely over the spa. 2. Position the locks for the tie-downs on the sides of the spa.
817G3 NO DIVING TILES DRAIN (1 ea) 0212318 817G1 (2 ea) 0532064 DRAIN (2 ea) 0212318 817G2 DRAIN Cascade Cover Plate 0663005 (2 ea) 0532064 (1 ea) 0212305-TRB (2 ea) 0212318 DRAIN PAGE 4
NOTE: FOR BEST RESULTS, READ EACH STEP CAREFULLY AND ENTIRELY BEFORE PROCEEDING TO THE NEXT. FILLING YOUR SPA GFCI Wipe the interior of the spa with a damp, soft cloth to remove any residue that may be on the surface. Fill with a garden hose by inserting the nozzle of the hose in the filter inlet (After filling is complete, remember to put the filter cartridge in place prior to starting the spa).As the spa is filling, check in the equipment access area for any leaks.
xStream Duo Pro only THERAPY OPERATING INSTRUCTIONS xStream Duo Pro Therapy Control Center This button increases the value on display. This button decreases the value on display. This button is not active on this model. DISPLAYING TIME OR TEMPERATURE Operates functions on therapy portion of Duo Pro Press The xStream Duo Pro spa has been designed for your maximum enjoyment and comfort, with two totally independent areas, one for swimming exercises and one for therapy.
THERAPY PROGRAMMING INSTRUCTIONS REFER TO PROGRAMMING INSTRUCTIONS ON PAGE 21 FOR QUICK PROGRAMMING STEPS A. PROGRAMMING MENU ..................................................... 3s Note: All programming functions are shown sequentially. To access any specific programming step, you have to enter programming from the beginning, as explained here. Press and hold for three (3) seconds until “dISC” is on the screen to enter the programming menu.
THERAPY PROGRAMMING INSTRUCTIONS E. HEAT DAYS & TEMPERATURE ............................................ Your spa is pre-programmed from factory to heat “All” days, “hd=A”. It has however the ability to be programmed for different temperatures on different days of the week. To do so, follow these steps: Example: Let's assume that you don’t normally use the spa between Mondays and Thursdays and you want to save on your electric bill by reducing the spa’s energy consumption. 1.
THERAPY ADVANCED PROGRAMMING INSTRUCTIONS DO NOT ENTER THIS SECTION UNLESS INSTRUCTED BY A QUALIFIED TECHNICIAN ** IMPROPER CHANGES MAY CAUSE MALFUNCTION OR DAMAGE YOUR SPA AND MAY VOID THE WARRANTY! ** ADVANCED FEATURES SETUP To exit programming mode, press , or at any point in the sequence or wait for 10 seconds (without pressing any button). A1. SETUP ("SU") .................................................................
SWIM OPERATING INSTRUCTIONS The xStream Series spas have been designed for your maximum enjoyment and comfort. Swim Control Center They have been engineered for energy efficiency, and the ICSTM electronic control center allows full programming of temperature and filtration cycles. With the ICSTM electronic control center you may program different temperatures for each and every day of the week, giving you all the tools for maximum comfort and energy savings.
SWIM OPERATING INSTRUCTIONS SETTING TEMPERATURE FOR A DAY. NOTE: This setting only alters the temperature for the rest of the day. Press this button to display water temperature. Press these buttons to select the desired temperature. Go to section B. HEAT DAYS & TEMPERATURE on page 13 to make permanent changes. NOTE: For full instructions on programming your ICSTM controller, go to the SWIM PROGRAMING INSTRUCTION section on page 13.
SWIM OPERATING INSTRUCTIONS SURROUND STEREO TURNING ON THE LIGHT Standard Light: Press LED Light: Press (OPTIONAL) to turn light on and off. once to turn underwater lights on. Pressing a second time will turn on Aquabrite/ Chromatherapy, if so equipped. Pressing a third time will turn lights off. For color/intensity programming, refer Aquabrite/Chromatherapy instructions below.
SWIM PROGRAMMING INSTRUCTIONS REFER TO PROGRAMMING INSTRUCTIONS ON PAGE 22 FOR QUICK PROGRAMMING STEPS A. PROGRAMMING MENU ..................................................... 3s Note: All programming functions are shown sequentially. To access any specific programming step, you have to enter programming as explained here. Press and hold for three (3) seconds until “dISC” is on the screen to enter the programming menu.
SWIM PROGRAMMING INSTRUCTIONS USE ARROWS TO CHANGE E. CLOCK AND CALENDAR SETTING ...................................... The display will sequence through the time and calender settings as 12/24 is HOUR pressed. Sequence is: “H=12” – 12-hr or “H=24” – 24-hr clock Hours setting Minutes setting Month setting Day setting Year setting Use and MINUTES MONTH DAY YEAR to change blinking digits. F. HEAT LOCK .......................................................................
SWIM ADVANCED PROGRAMMING INSTRUCTIONS DO NOT ENTER THIS SECTION UNLESS INSTRUCTED BY A QUALIFIED TECHNICIAN ** IMPROPER CHANGES MAY CAUSE MALFUNCTION OR DAMAGE YOUR SPA AND MAY VOID THE WARRANTY! ** ADVANCED FEATURES SETUP To exit programming mode at any point in the sequence, press any button other than , or , or wait for 10 seconds (without pressing any button). A1. SETUP ("SU") .................................................................
THERAPY JET OPERATION Your xStream Swim Spa’s therapy section is designed with a unique jet system to allow you to select a wide variety of massage patterns. The following is a description of the various types of jets and their operation you may use to tailor your spa to your specific massage needs. A) EURO CLUSTER MASSAGE JET B) DIRECTIONAL MASSAGE JETS These jets are used for back, neck and shoulder massage.
SAFETY FEATURES A. FREEZE PROTECTION If the temperature in the spa plumbing falls below 10°C (50°F), the water pump will turn on low speed and run for 30 seconds. After 30 seconds, if the water is still at 10°C (50°F), the heater will turn on and raise the temperature 2°C (10°F). The top side control will display the message "ICE" to indicate potential freeze conditions. B.
SPA MAINTENANCE Your spa is manufactured with the highest quality and most durable materials available. A spa care and maintenance program is recommended to increase your comfort, maintain the spa’s reliability, and protect your investment. FILTER MAINTENANCE COVER MAINTENANCE Your Spa is designed with the most efficient top loading filtration system in the industry. Filter maintenance is the most critical factor in keeping your spa water clean.
SPA MAINTENANCE WINTERIZING YOUR SPA Most Hot Tub enthusiasts will agree that there is no better time to enjoy their spa then in colder winter months. Although your Spa has been designed and engineered for year-round use in any climate, if you chose to leave it empty in the winter time, there are precautions you should take. 1. Make sure that all power to the spa is “turned off”. We recommend shutting off the breaker to the spa. 2. The next step is to fully drain the spa.
DIAGNOSTIC & TROUBLESHOOTING Resetting Your Spa Like your PC at home, your spa electronics could get corrupted by electrical surges and operate improperly. If your spa system is not operating properly or shows any of the following messages, please reset it before calling for service to see if the malfunction disappears. To reset the spa, shut off the breaker for 5 sec. and turn it back on. SYMPTOM MEANING ACTION Spa Inoperative Power failure outside of spa.
xStream Duo Pro Therapy Pack Programming Instructions 3s Self Test (2 min.) Rev. Date: 10/17/2008 FACTORY DEFAULT SETTINGS If display does not show AH or ECO, call a service tech. DOMESTIC EXPORT Auto-Heat or ECOnomy mode or Assure default hours are: Cycles through Filtration hours.
xStream, xStream Pro and xStream Duo Pro Swim Pack Programming Instructions 3s Self Test Function not applicable to Swim Packs. If display shows AH or ECO, call a service tech. or Rev. Date: 10/9/2008 The Swim Pack has a Circulation Pump. Auto-Heat and ECOnomy modes do not apply.
MIAMI FLORIDA DM Industries, Ltd., 2320 Northwest 147th Street, Miami, Florida 33054 Email: customercare@dmindustries.com and techhelp@dmindustries.com www.dmindustries.com File: xStream_Own_Man_0905a.