Installation Instructions (continued):
Connecting 1/4” tubing from Water Line to System. (See Figure 6):
1. Determine the length of 1/4” Tubing (D) from Inlet Valve (G) to the inlet of Head Assembly
(A) by holding tubing in place ensuring it’s of appropriate length. Cut the tubing square
with a utility knife.
CAUTION: Don’t kink tubing as this will impede water flow.
2. Wet one end of the tubing with water and push it onto the guide tube of the valve until it stops.
3. Wrap Teflon Tape around the thread of the valve, and hand-screw the Inlet Compression
Nut (H) on the valve and tighten with adjustable wrench.
4. Push other end of the tubing into the inlet of Head Assembly (A) by referring the instruction
of “Tubing Connection with Push-in Fitting”.
Connecting 1/4” tubing from System to Faucet. (See Figure 6):
1. Determine the length of 1/4” Tubing (D) from the outlet of Head Assembly (A) to the stem of
the Faucet (I) by holding tubing in place ensuring it’s of appropriate length. Cut the tubing
square with a utility knife.
CAUTION: Don’t kink tubing as this will impede water flow.
2. Gently slide Faucet Compression Nut (Q) down over the tubing. Follow with Ferrule (P). Push
Insert (O) into the end of the tubing.
3. Wrap Teflon Tape around the thread of the stem.
4. Firmly push the tubing into the stem of Faucet (I) until it stops. Hand-screw the nut onto the
threads of the stem. Tighten with wrench.
CAUTION: Don’t overtighten the compression nut.
5. Push other end of the tubing into the water outlet of Head Assembly (A) by referring the
instruction of “Tubing Connection with Push-in Fitting.
Figure 7.
Figure 8. Figure 9. Backstop
O-Ring
11/16”
Tubing Connection with Push-in Fittings. (See Figure 7, 8 and 9):
1. Take off the blue horseshoe clip from collet. See Figure 7;
2. Pull out and discard the protect plug by pushing the collet inward and holding with fingers.
See Figure 8;
3. Insert Tubing (D) into the collet. Full engagement is 11/16” length of the tubing into the
fitting. (See Figure 9):
NOTE: Ensure tubing is pushed all the way to backstop.
4. Put blue horseshoe clip back on collet.
5. To pull tubing out, simply repeat Steps 1 to 2.