Installation Guide
6
1. Turn Inlet Valve (G) to open position and the cold water sink faucet to the closed position.
2. Slowly open the cold water supply valve that you closed at the beginning of this installation.
3. Open Faucet (J) to purge air from the system. When the water runs smooth
with no bubbles or spurting, close the faucet and check for leaks for all fittings.
4. Open the Faucet (J) again to rinse the system.
CAUTION: Let water run 15 minutes before using.
NOTE: Initially, there may be some dark discolouration of the water (carbon deposits). This
condition is normal and will disappear quickly.
Start-up Instructions:
Figure 6. Figure 7. Figure 8. BackstopO-Ring
11/16”
Installation Instructions (continued):
Tubing Connection with Push-in Fittings. (See Figure 6, 7 and 8):
26. Take off the blue horseshoe clip from collet. See Figure 6:
27. Pull out and discard the protect plug by pushing the collet inward and holding with
fingers. See Figure 7:
28. Insert Tubing (E) into the collet. Full engagement is 11/16” length of the tubing into the
fitting. See Figure 8:
NOTE: Ensure tubing is pushed all the way to backstop.
29. Put blue horseshoe clip back on collet.
30. To pull tubing out, simply repeat Steps 26 to 27.
Horseshoe
Clip
Collet