Installation Guide
14
Annual Maintenance:
NOTE: Sanitizing of unit is recommended.
1. Perform steps 1 through 5 in the Six Month System Maintenance.
NOTE: If not sanitizing the system skip to step 2 - 6.
2. Remove the RO membrane from the housing and rest in a clean sanitary place. (Refer
to Membrane Replacement section for directions on removing the membrane).
Replace cap onto empty membrane housing and re-connect tubing.
3. Remove the filters out from the two vertical filter housings. Measure and pour either ½ cup
of hydrogen peroxide or 2 table spoons of common household bleach into the 1st filter
housing and re-attach the 2 empty filter housings onto unit with the supplied wrench.
4. With the RO Faucet in the closed position turn on the incoming water supply to the
system by turning the inlet valve counter clockwise. Wait 1 minute for the unit to pressurize.
Turn on the RO Faucet and let the water run for 30 seconds. Turn off the RO faucet and let
the unit rest for 2 minutes. Finally, open the RO faucet and let the water run for 5 more
minutes.
5. Turn off the incoming water supply to the system by turning the inlet valve clockwise until it
stops. Keep the RO faucet open until the storage tank is completely drained.
6. Open the membrane housing and re-install the RO membrane while making sure not to
kink the O-rings. (Refer to Membrane Replacement Section).
For Model VRO-3U:
1. Remove filter housings at stages 1 and 3 and empty the water.
2. Insert a new Carbon Block filter (white end cap and plastic netting) into the 1st filter housing
which is the one on the water inlet side of the RO system and re-install housing to the head.
Tighten with the supplied wrench.
3. Insert a new Carbon Block filter (white end cap and plastic netting) into 2nd filter housing
and re-install housing to the head. Tighten with the supplied wrench.
Continue to Step 7.
For Model VRO-4U:
1. Remove the filter housings at stages 1 and 2 and empty the water.
2. Insert a new Sediment filter (cloth like appearance) into the 1st filter housing which is the
one on the water inlet side (red tubing) of the RO system and re-install housing to the head.
Tighten with the supplied wrench.
3. Insert a new Carbon Block filter (white end cap and plastic netting) into 2nd filter housing
and re-install housings to the head. Tighten with the supplied wrench.
4. The carbon in-line filter is located between the RO faucet and storage tank. It is
attached to the RO Membrane with brackets. Remove it by loosening the fitting on both
ends of the post filter and replace with new filter. (Refer to the Inline Post Carbon Filter
Replacement Section)
Continue to Step 7.
NOTE: This is a good time to check the air pressure in your storage tank. For instructions please
refer to the Check Air Pressure in the Tank Section.
7. Perform steps 6 through 9 in the Six Month System Maintenance section for startup directions.