Installation Guide
19
Performance Data Sheet:
The VRO-3U has been tested and certified by NSF International according to NSF/ANSI 42 and
58 and the VRO-4U has been tested and certified by NSF International according to NSF/ANSI
58 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 58. While testing was performed under standard laboratory conditions,
actual performance may vary.
Performance Claims for VRO-3U and VRO-4U
Substance
Average influent
challenge
concentration
Maximum
allowable product
water level
Percent
reduction
requirement
Tested Performance
Product water
level
1
Percent
Reduction
1
NSF Standard 42
Aesthetic Chlorine
(VRO-3U post filter only)
2.0 mg/L ± 10% ≥ 50% 91.8%
Particulate Class III
(VRO-3U post filter only)
10,000/mL ≥ 85% 99.9%
NSF Standard 58
Arsenic
(pentavalent)
0.30 mg/L ± 10% 0.010 mg/L 0.007 mg/L 99.2%
Barium 10.0 mg/L ± 10% 2.0 mg/L 0.43 mg/L 97.6%
Cadmium 0.03 mg/L ± 10% 0.005 mg/L 0.0014 mg/L 98.1%
Chromium
(Hexavalent)
0.30 mg/L ± 10% 0.10 mg/L 0.009 mg/L 98.5%
Chromium
(Trivalent)
0.30 mg/L ± 10% 0.10 mg/L 0.010 mg/L 96.7%
Copper 3.0 mg/L ± 10% 1.3 mg/L 0.1 mg/L 98.7%
Fluoride 8.0 mg/L ± 10% 1.5 mg/L 0.4 mg/L 95.7%
Lead 0.15 mg/L ± 10% 0.010 mg/L 0.005 mg/L 96.6%
Radium 226/228 25 pCi/L ± 10% 5 pCi/L 5 pCi/L 80%
Selenium 0.10 mg/L ± 10% 0.05 mg/L 0.002 mg/L 97.9%
TDS 750 ± 40 mg/L 187 mg/L 51 mg/L 93%
Cyst ≥ 50,000 /mL 99.95% 99.99%
Turbidity 11 ± 1 NTU 0.5 NTU < 0.1 NTU > 99.1%
Daily Production Rate: 23.30 gpd
Efficiency:
2
16.03
%
Recovery:
3
30.11%
Manufactured and warranted by:
GHP Group
USA: 6440 W. Howard Street, Niles, Illinois 60714
Canada: 271 Massey Road, Guelph, Ontario, N1K 1B2
Tested by NSF International according to NSF/ANSI standard 42 and 58.
Efficiency rating means the percentage of the influent water to the system that is available to the user as
reverse osmosis treated water under operating conditions that appropriate typical daily usage.
Recovery rating means the percentage of the influent water to the membrane portion of the system that is
available to the user as reverse osmosis treated water when the system is operated without a storage tank or
when the storage tank is bypassed.
1
2
3