Installation Guide

8
Installation Instructions (continued):
1. Wash your hands before removing the plastic packaging from the RO membrane
2. Remove the tube connection from the RO membrane cap.
3. Loosen the cap by using the wrench provided in a counterclockwise direction.
4. Lubricate the O-rings on the new membrane with water. Insert the end with the two black
O-rings first onto the standpipe within the filter housing.
5. Once the membrane has been inserted into the housing give a firm push to properly seat
the membrane.
6. Check to see that the O-ring is in the cap properly seated. Replace membrane housing
cap and tighten with the supplied wrench in the clockwise direction.
5. Make sure the black rubber gasket is adhered to the inside wall of the clamp and place
the clamp assembly over the drain pipe. Insert ⁄” black tube into the drilled hole. Tighten
the clamp.
CAUTION: Do not overtighten the screws, it may crack the clamp.
CAUTION: The black 3/8” drain tube must be as SHORT and STRAIGHT as possible to the drain
saddle, making a downward slope from the faucet to the drain saddle to allow
for proper drainage. This is a gravity fed line and if there is any bend or dip in the
tubing, the rinse water will not flow into the drain properly. Water may back up and
come out the air gap hole in the faucet.
Figure 7. Figure 8.
Figure 9.
Drain Tubing
Drain Clamp
Black Rubber
Gasket
Front Plate
Drain Pipe
Drain Clamp
Back Plate
Mount Drain
Valve Here
Never
Mount
Here
3
/
8
Black Line
Drain Tubing
Drain Clamp
Black Rubber
Gasket
Front Plate
Drain Pipe
Drain Clamp
Back Plate
Mount Drain
Valve Here
Never
Mount
Here
3
/
8
Black Line
2 Rubber
O-Rings
This end inserted
into housing rst
Wrench
Tighten Housing Cap by
Turning Wrench Clockwise
Membrane Housing Standpipe
2 Rubber
O-Rings
Installing the Membrane into the Membrane Housing (see figure 9):