Instructions / Assembly
9
installation of pRoduCt wateR fauCet:
A ⁄” to ¼” quick connect fitting is supplied if you want to by pass the air gap connection on
the faucet.
In this case the ¼” black drain tubing connects to one end of the quick connect and the ⁄”
black tubing connects to the other end of the quick connect. The ⁄” line then goes to the
saddle drain clamp connection. Some provinces/states have a requirement for connection of
drain line to air gap faucet.
CAUTION: The installation of this system must be in accordance with all provincial/state and/
or local laws and regulations regarding plumbing and electrical. Please consult
regulations concerning the air gap connection on RO faucets in your province or state.
To Bypass the Air Gap Faucet
RO Product Water Connection
Step 3 Loosen stem-nut on the faucet.
Step 4 Slide Chrome plate and black rubber washer onto the faucet stem. The chrome plate,
large rubber faucet washer and faucet body are above sink or countertop.
Step 5 Feed the ⁄” and ¼” black tubing through the pre-drilled hole in the sink/counter.
Step 6 Place the faucet through the drilled faucet hole and add spacer, securing plate, star
lock washer and stem nut.
Step 7 Tighten stem nut firmly while aligning faucet in the desired location.
Step 8 Attach quick connect to stem of air gap faucet.
Step 9 The ⁄ blue tubing is attached to the quick connect (product water) from RO unit.
⁄” Side of Connector ¼” Side of Connector
Counter top
Chrome Plate
Rubber Washer
Counter top
Securing Plate
Spacer
L
Quick connect for
RO to faucet
ock Washer
¼” Nut
3
/
8
” Blue Line
Product Water