6. Seasonal Use Maintenance Requirements
If your system is only being used seasonally, it must be stored properly for the winter. Shut off the inlet and outlet water valves and drain all
water from the system. Cap both the inlet port and the outlet port, to prevent entry of insects and small animals.
Remove the filters from the system and discard them in the trash.
Before placing the system back in service, it is recommended that the household plumbing procedures described in section 5 be followed.
Install new filters in the system. Do not re-install filters used during the previous season.
Problem Possible Cause Suggested Solution
Pressure Drop
(More than 40 psi loss at
8GPM).
Filter(s) clogged. Replace filter cartridge.
Leaking water from housing. Housing not sealed properly.
Excessive water pressure (beyond 80 psi).
Water Hammer causing pressure spikes.
Depressurize, lubricate threads and retighten.
Install pressure regulator ahead of system.
Install a Water Hammer* Arrestor in system.
Water is milky. Small air bubbles are trapped in water.
Air purging from new filters / system.
Leave tap on for short time.
Find source of air bubbles and correct (flush more).
System is Vibrating. Not mounted securely.
Water Hammer* causing vibrations.
Secure fasteners.
Install a Water Hammer* Arrestor in system.
Outlet water has bad taste. Filters not installed.
Filter(s) / Housing(s) not seated properly.
Testing / source identification / additional pre-treatment
may be required.
Ensure filters are in position.
Ensure filters are correctly seated in the housing, and the
housings are seating properly.
Testing should be conducted to determine cause of bad
taste. Additional pre-treatment may be required.
7. Troubleshooting Guide
* Water Hammer: Sudden closure of a control valve or stopping of a pump produces excess pressure in a pipeline. The hydraulic engineer, water supply designer and pumping
system operator have the responsibility to ensure the surges due to Water Hammer are within acceptable limits and can be dampened as quickly as possible.
Note: If you experience trouble with your system other than the symptoms described above, please visit www.ghpgroupinc.com, or contact
the Customer Service Department at 1-866-253-0447.