Product Manual

26 ENG
Prepare the alternating current power supply line using three-pole cable with minimum
section per wire of 1 mm2 and suitable isolation for the methods and environment of use
and compliant with the regulations in force.
Make the connection to the AC power line by means of a plug connection with an
adequate ow rate compliant with current regulations or prepare an omnipolar
magnetothermal dierential switch with a capacity of 6 amps and with contact opening
of at least 3 mm or nevertheless in compliance with current regulations.
Once installation has been completed, check the continuity of the earth circuit and
carry out all the electrical safety tests provided for by current regulations.
Protect and lock the cables in order to prevent accidental pulling of the cable from
disconnecting it from the connections or coming into contact with hot parts with a
temperature above 50°C or with sharp parts.
It is recommended that the installation of the power supply lines is carried out by qualied
personnel who will check the compliance of the unit with the regulations in force and
issue the relative certications of conformity.
STANDARD BATTERY PROTECTION SETTINGS
12 V cut- out V 12 V cut- in V 24 V cut- out V 24 V cut- in V
12 V stacco V 12 V attacco V 24 V stacco V 12 V attacco V
10.4 11.7 22.8 24.2
CABLE DIMENSIONS: CONNECTION BETWEEN THE BATTERY AND ELECTRONIC UNIT
Section (mm
2
) 2.5 4 6 10
Max. length m line at 12V 2.5 4 6 10
Max. length m line at 24V 5 8 12 20
7. START-UP
Once the plug is connected to the power outlet, the fridge will start-up automatically in
thermostat mode and no further operations are required for its correct operations.
For a reasonable arrangement and storage of food follow the table below: