- 24 -
Wired Zones Configuration
Thecontrolpanelcanbeconfiguredwithuptotwowiredsensors.Thewiredsensorsarehardwirecontactloops
connectedtotheloopinputterminalsonthecontrolpanelterminalblock
Configuringthewiredsensorsintothecontrolpanelinvolvesselectingwiredsensortype,wiredzonenumber,
normalstate(open,closed,orend-of-lineresistor),andselectingtheotheroptionsforthesensor..
Toaccessthesesettingsfromthecontrolpanel,goto:
Menu > Settings > Installer Toolbox > Zones, Key Fobs, Keypads > Wired Zones
Wi red Sensor Reporti ng Codes
l WiredSensor#1=ReportsasSensor#135
l WiredSensor#2=ReportsasSensor#136
List of Settings
Theoptionsthatcanbesetforeachwiredsensorincludethefollowing(seebelowthislistfordetailed
descriptions):
l Sensor Type: Exit/entry,perimeter,interior,etc.
l Wired Zone: Selectnumber1or2.
l Voice Descriptor: Selectthewordsthepanelvoiceusestodescribethesensor.
l Name: Nameassignedtothesensorthatisusedforvoiceannunciationandinuserinterfaces.
l Chime: Enableanddisablethechimeoptionforthesensor.
l Chime Tone: Selectfromtheavailabletonesforthechime.
l Voice: Enableanddisablethevoiceoptionforthesensor.
l Dialer Delay: Delayedorinstantcommunicatorreportsforthesensor(delaytimeissetbydialerabort
window).
l Reports: Communicatorreportsornocommunicatorreportsforthesensor.
l Normal State: Normallyopen,closed,orend-of-lineresistorloop.
l Equipment Age: Identifiesthesensoraseitheranewdevice(i.e.,initialinstallation)oranexistingdevice
thatwaspreviouslyinstalledinthesystem.
Wired Sensor Types
Eachwiredsensorneedstobeassignedtoasensortype.
Selectthesensortypethatmatchesthewiredsensor’sfunction.
Wired Sensor Types
(00)Unused (06)24-hourSilentAlarm