User's Manual

Smart Hub Setup Guide
- 36 -
Entry and Exit Settings
Thissectioncontainsdescriptions,defaultvalues,andnotesabouttheEntryandExitsettings.
Toaccessthesesettingsfromthecontrolpanel,goto:
Menu > Settings > Installer Toolbox > Entry and Exit
FromtheEntryandExitscreen,youcanviewandconfigurethefollowingsettings.
Exit Delay (in seconds 45-120)
DEFAULT: 60 seconds
(NOTE: Default Setting Required f or SIA CP-01 Compl i ance)
TheExitDelaycanbesetfrom45to120seconds.
NOTE:ThisdefaultcanbechangedwithoutaffectingSIACP-01compliance.
Entry Delay 1 (in seconds 30-240)
DEFAULT: 30 seconds
(NOTE: Default Setting Required f or SIA CP-01 Compl i ance)
TheEntryDelay#1canbesetfrom30to240seconds.
l Thedefault(30)setstheEntryDelay#1to30seconds.
l TochangetheEntryDelay#1,enteravaluefrom(30-240)seconds.
IMPORTANT:InaccordancewithSIACP-01,thesumoftheAbortWindowDialerDelayandtheEntryDelay
cannotexceedoneminute.
Entry Delay 2 (in seconds 30-240)
DEFAULT: 30 seconds
(NOTE: Default Setting Required f or SIA CP-01 Compl i ance)
TheEntryDelay#2canbesetfrom30to240seconds.
l Thedefault(45)setstheEntryDelay#2to45seconds.
l TochangetheEntryDelay#2,enteravaluefrom(30-240)seconds.
IMPORTANT:InaccordancewithSIACP-01,thesumoftheAbortWindowDialerDelayandtheEntryDelay
cannotexceedoneminute.