User's Manual

Configure System Settings: System Options Settings
- 57 -
l Enabledonburglaryalarm
l Enabledonfirealarm
l Enabledonanyalarm
l Enabledonanysystemtrouble
l Enabledfollowssounderalarmandstatus
l Enabledfollowsexitandentrybeeps
Cross Sensor 1, Cross Sensor 2, and Configure Cross Sensors
DEFAULT: Disabled
Thecontrolpanelcanbeconfiguredsosensors1and2mustbothbeviolatedduringasettimetotriggeranalarm.
Thisiscalled"crosssensor"verification.Whenenabled,ifonlyonesensorisviolated,thealarmwillnottrigger,
butatroublereportwillbesentforthesensorthattriggered.
NOTE:COandfirezonecannotbeusedforcrosssensors.
l Thedefaultsettingdisablesthecrosssensorfeature.
l Tousethecrosssensorfeature,selectenabled.
NOTE:Formoreinformation,seetheCrosssensortimeoutsetting(below).
Cross Sensor Timeout (in seconds)
DEFAULT: 10 seconds
Thecrosssensortimeoutisthemaximumperiodoftimeallowedbetweenviolationofcrosssensorsthatwill
triggeranalarm.Ifbothsensorsareviolatedwithinthistimeperiod,analarmwillbetriggered.Ifbothsensorsare
notviolatedwithinthistimeperiod,analarmwillnotbetriggered.
NOTE:Crosssensorverificationmustbeenabledforthisfeaturetofunction.
l Thedefaultsettingsetsthecrosssensortimeoutat10seconds.
l Tochangethecrosssensortimeoutduration,select(11-120)seconds.
Cameras Require Admin Code
DEFAULT: Disabled
LimitsaccesstoonlyAdminusers.Ifthisoptionisenabled,userswillbepromptedtoenteravalidAdminPIN
codeinordertoviewthedevice.