User's Manual

Regulatory Information: Default Settings for SIA CP-01-2014 Compliance
- 81 -
Default Settings for SIA CP-01-2014 Compliance
Severalofthecontrolpanel'ssystemsettingsareconfigurableandhavetheirdefaultvaluespre-settoensure
compliancewiththeindustrystandard:American National Standards Institute / Security Industry
AssociationANSI/SIA CP-01-2014(Control Panel Standard - Features for False Alarm Reduction).
IMPORTANT:Notethatalloftheothersystemsettingsandfunctionsthatarerequiredinordertocomplywith
SIA CP-01-2014arepermanentlysetonthepanel(hardcoded)andcannotbechanged.
Thefollowingtableprovidesaquickreferenceforalloftheconfigurablesystemsettingswhosedefaultvalues
ensureSIA CP-01-2014compliance.
Vivint Setting Name (SIA Name, if different) SIA CP-01-2014 Default Value Value Range
ExitDelay(ExitTime) 60Seconds 45-120Seconds
ProgressAnnunciation/DisableforSilentExit Enabled EnabledorDisabled
ExitDelayRestart(ExitTimeRestart) Enabled EnabledorDisabled
AutoStay(AutoStayArmonUnvacatedPremises) Enabled EnabledorDisabled
EntryDelay1 30Seconds 30-240Seconds
EntryDelay2 45Seconds 30-240Seconds
RemoteArmingExitTime&ProgressAnnunciation Enabled EnabledorDisabled
WirelessSensorDialerDelay(AbortWindowTime
forNon-FireZones)
Enabled EnabledorDisabled
WirelessSensorDialerDelayTime(AbortWindow
TimeforNon-FireZones)
30Seconds Atleast15seconds
AbortWindowDialerDelay(AbortWindowTime) 30Seconds 15,30,or45Seconds
AbortWindowAnnunciation Enabled EnabledorDisabled
CancelTime(CancelWindow) 5Minutes 5-255Minutes
CancelDisplay(CancelAnnunciation) Enabled EnabledorDisabled
DuressFeature Disabled DisabledorEnabled
CrossZoning Disabled
DisabledorEnabled
(using2ormorezones)
SwingerShutdownCount 2Trips 1-6Trips
SwingerShutdownDisable Enabled EnabledorDisabled
FireAlarmVerification Disabled
Disabled(ifsensorscan
self-verify)orEnabled
SystemTest IndependentlyActivated
Active,Untested,
Complete
Communications(TransmitTestSignalsto
MonitoringStation)
Disabled DisabledorEnabled