User Manual

38
Response Format:
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Resp1
Resp2
Data1
Data2
ChkSum
Extended Response
0xFF
0x01
0x00
Hour
Minute
Second
--
Command format: Set
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Cmd1
Cmd2
Data1
Data2
ChkSum
Set timer LED off -
hour
0xFF
0x01
0x9C
0x6D
0x00
Hour
--
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Cmd1
Cmd2
Data1
Data2
ChkSum
Set timer LED off
min/sec
0xFF
0x01
0x9E
0x6D
Minute
Second
--
Response Format:
Byte number
1
2
3
4
Byte Definition
Sync
Addr
Faults
ChkSum
General Response
0xFF
0x01
--
--
5.1.7.11 DI/DO status
Command format: Get
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Cmd1
Cmd2
Data1
Data2
ChkSum
Query DIO status
0xFF
0x01
0x20
0x6D
0x00
0x00
--
Response Format:
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Resp1
Resp2
Data1
Data2
ChkSum
Extended Response
0xFF
0x01
0x00
0x24
DI state
DO state
--
DIO's state: (0) Lo/ (1) Hi
5.1.7.12 Hysteresis/Oversample of light sensor trigger
Command format: Get
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Cmd1
Cmd2
Data1
Data2
ChkSum
Query ambient
hysteresis/oversample
0xFF
0x01
0x22
0x6D
0x00
0x00
--
Response Format:
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Resp1
Resp2
Data1
Data2
ChkSum
Extended Response
0xFF
0x01
0x00
0x26
Hysteresis
Oversample
--