User Manual

48
Response Format:
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Resp1
Resp2
Data1
Data2
ChkSum
Extended Response
0xFF
0x01
Year MSB
Year LSB
Month
Day
--
5.1.9.9 Factory time
Command format: Get
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Cmd1
Cmd2
Data1
Data2
ChkSum
Query Factory Time
0xFF
0x01
0x1C
0x73
0x00
0x00
--
Response Format:
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Resp1
Resp2
Data1
Data2
ChkSum
Extended Response
0xFF
0x01
0x00
Hour
Minute
Second
--
5.1.10 Set brightness level (0x7D)
This command set CaMate’s brightness level to the desired percentage.
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Cmd1
Cmd2
Data1
Data2
ChkSum
Set brightness level
0xFF
0x01
0x00
0x7D
0x00
Brightness
%
--
Response Format:
Byte number
1
2
3
4
Byte Definition
Sync
Addr
Faults
ChkSum
General Response
0xFF
0x01
--
--
5.1.11 Set ambient threshold level (0x7F)
This command set CaMate’s ambient threshold level to the desired percentage.
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Cmd1
Cmd2
Data1
Data2
ChkSum
Set Factory Time -
hour
0xFF
0x01
0x00
0x7F
0x00
Threshold
%
--
Response Format:
Byte number
1
2
3
4
Byte Definition
Sync
Addr
Faults
ChkSum
General Response
0xFF
0x01
--
--