User Manual

VIVOTEK
User's Manual - 397
© 2019 VIVOTEK INC. All Right Reserved
267
PARAMETER VALUE DESCRIPTION
*Only available when
capability_peripheral_c<0~(n-1)>_washer_supp
ort=1
heater_supportstatus N/A Get the support status of heater control system.
*Only available when
capability_peripheral_c<0~(n-1)>_heater_suppo
rt=1
heater_status N/A
Get the current heater status.
Normally it will be 'auto', it means the heater
device is control by internal algorithm to keep in
a suitable environment; Otherwise is 'trigger', it
means the heater device is force enable to heat
to an internal condition.‘trigger’ status will be
transfer to ‘auto’ after reach the internal
condition.
*Only available when
capability_peripheral_c<0~(n-1)>_heater_suppo
rt=1
© 2019 VIVOTEK INC. All Right Reserved
268
8.37 Optimized IR control
(capability_daynight_c<0~(n-1)>_optimizedir > 0)
Note: This request requires Administrator privileges.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/admin/optimizedir.cgi?function=<value>[&channel=<value
>]
PARAMETER VALUE DESCRIPTION
channel 0~"capability_nvideoin"-1
Channel of the video source.
function getstatus,
onetimeauto
"onetimeauto": Camera will automatically adjust the IR
zone one time only.
"getstatus"
: Information of optimized IR control status and
return value as below:
optimizedir_c<0~(n-1)>_irmode:
Indicate the IR current mode, available value is “auto” and
“manual” mode.
optimizedir_c<0~(n-1)>_irnum:
The number of IR that camera supports.
optimizedir_c<0~(n-1)>_irstrength:
Only available when irmode is set as manual. Its a set of
integers, which indicate the strength of each IR LED (e.g.
23,45,100,100).
optimizedir_c<0~(n-1)>_irstatus:
Current IR status, normal / adjusting:
"normal": the IR LED strength has been fixed.
"adjusting": the IR LED strength is adjusting.
Example: