DeviceID80h(128)canbeusedtoconfigureanydevicenomatterwhatthedeviceIDofdevicesis
(theMasterdeviceIDonlysupportsconfigurationandcontrolfunctions,butnotquery).TheMaster
DeviceIDcanbeusedtoconfiguremultipledevicesconnectedtogetherwiththesameconfiguration
profile.Iftheapplytoallcheckboxisselected,thesoftwarewillusetheMasterdeviceIDtoproceed
withconfiguration.
DefaultDeviceIDofmodels
Model DeviceID Remarks
IR850 CM48I8 ‐1040 1
CM48I8‐2040 2
CM48I8‐4080 3
CM48I8‐90120 4
CM48I8‐180 5
IR940 CM48I9 ‐1040 11
CM48I9‐2040 12
CM48I9‐4080 13
CM48I9‐90120 14
CM48I9‐180 15
W5 CM48W5‐1040 21
CM48W5‐2040 22
CM48W5‐4080 23
CM48W5‐90120 24
CM48W5‐180 25
Model DeviceID Remarks
IR850
motorized
CM48I8A‐1040 31
CM48I8A‐2040 32
CM48I8A‐4080 33
CM48I8A‐90120 34
IR940
motorized
CM48I9A‐1040 41
CM48I9A‐2040 42
CM48I9A‐4080 43
CM48I9A‐90120 44
W5
motorized
CM48W5A‐1040 51
CM48W5A‐2040 52
CM48W5A‐4080 53
CM48W5A‐90120 54
Baudrate
BaudratesetsthecommunicationspeedofCaMatedevicesontheRS485interface.TheMax.rateis
115,200,andthemin.is1,200.Thedefaultbaudrateis38,400.Remembertochangethebaudrateof
applicationsoftwareimmediatelyafteryouchangethebaudrateofaCaMatedevice.Mismatched
BaudratesettingbetweenaPCandCaMatedeviceswillfailtheRS485communications.Insome
computers,themax.baudratemayonlyreach38,400.
ItisrecommendednottochangethebaudrateofCaMatedevicesbecauseoncethebaudrateis
changedandforgotten,theonlywayistorunthePCsoftwareistoprobethebaudrate.