User Manual

36
5.1.7.7 Device ID address
Command format: Get
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Cmd1
Cmd2
Data1
Data2
ChkSum
Query device ID
address
0xFF
0x01
0x0E
0x6D
0x00
0x00
--
Response Format:
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Resp1
Resp2
Data1
Data2
ChkSum
Extended Response
0xFF
0x01
0x00
0x00
0x00
Device ID
address
--
Device ID address: 1~127
Command format: Set
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Cmd1
Cmd2
Data1
Data2
ChkSum
Set device ID
address
0xFF
0x01
0x8E
0x6D
0x00
Device ID
address
--
Response Format:
Byte number
1
2
3
4
Byte Definition
Sync
Addr
Faults
ChkSum
General Response
0xFF
0x01
--
--
5.1.7.8 Clock time
This command returns the time of clock in MCU. Due to no battery is installed in CaMate, the clock data
will reset if power is off.
Command format: Get
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Cmd1
Cmd2
Data1
Data2
ChkSum
Query Clock time
0xFF
0x01
0x14
0x6D
0x00
0x00
--
Response Format:
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Resp1
Resp2
Data1
Data2
ChkSum
Extended Response
0xFF
0x01
0x00
Hour
Minute
Second
--
Command format: Set
Byte number
1
2
3
4
5
6
7
Byte Definition
Sync
Addr
Cmd1
Cmd2
Data1
Data2
ChkSum
Set Clock time -
hour
0xFF
0x01
0x94
0x6D
0x00
Hour
--
Byte number
1
2
3
4
5
6
7