User's Manual
Table Of Contents
- Overview
- Using Web Browsers
- Using VIVOTEK Recording Software
- Using 3GPP-compatible Mobile Devices
- Using RTSP Players
- Main Page
- Client Settings
- Configuration
- System > General settings
- System > Homepage layout
- System > Logs
- System > Parameters
- System > Maintenance
- Media > Image
- Media > Video
- Media > Video
- Media > Audio
- Network > General settings
- Network > Streaming protocols
- Network > SNMP (Simple Network Management Protocol)
- Network > FTP
- Bonjour
- Security > User accounts
- Security > HTTPS (Hypertext Transfer Protocol over SSL)
- Security > Access List
- PTZ > PTZ settings
- Event > Event settings
- Applications > Motion detection
- Applications > Digital input
- Applications > Tampering detection
- Applications > Audio detection
- Applications > Package management - a.k.a., VADP (VIVOTEK Application Development Platform)
- Recording > Recording settings
- Local storage > Storage management
- Local storage > Content management
- Appendix
VIVOTEK
176 - User's Manual
* We support this parameter when the
version number (httpversion) is equal
or greater than 0302a.
* Only available when
"capability_image_c<0~(n-1)>_expo
sure_mode" !=0
irismode fixed, indoor, outdoor
<product dependent>
4/4 Control DC-Iris mode.
"outdoor": Auto-setting DC-Iris to
get best quality, but easy to meet
rolling or flicker effect in indoor
environment.
"indoor": Avoid rolling and flicker
effect first.
"fixed": Open the iris to maximum.
* Only available when
"capability_image_c<0~(n-1)>_iristy
pe"=dciris
piris_mode
<product
dependent>
manual, indoor, outdoor,- 1/4 Control P-Iris mode.
"outdoor": Auto-setting P-Iris to get
best quality, but easy to meet rolling or
flicker effect in indoor environment.
"indoor": Avoid rolling and flicker
effect first.
"manual": Manual set P-Iris by
"piris_position".
"-": not support. (only available when
"capability_image_c<0~(n-1)>_sens
ortype" is "smartsensor")
* Only available when
"capability_image_c<0~(n-1)>_iristy
pe"=piris
piris_position
<product
dependent>
1~100 1/4 Manual set P-Iris.
1: Open <-> 100: Close
* Only valid when
"piris_mode"=manual or
"capability_image_c<0~(n-1)>_sens
ortype" is "smartsensor"
* Only available when