NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
language_i7 :
简体中文
language_i8 :
繁體中文
customlanguage_max
count
0,<positive
integer>
0/6
Maximum number of custom languages
supported on the server.
customlanguage_coun
t
0,<positive
integer>
0/6
Number of custom languages which have
been uploaded to the server.
customlanguage_i<0~
(maxcount-1)>
string
0/6
Custom language name.
7.2 Status
Group: status
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
di_i<0~(capability_ndi-1)>
<product dependent>
<boolean>
1/7
0 => Inactive, normal
1 => Active, triggered
(capability_ndi > 0)
do_i<0~(capability_ndo-1)>
<product dependent>
<boolean>
1/7
0 => Inactive, normal
1 => Active, triggered
(capability_ndo > 0)
onlinenum_rtsp
0,<positive
integer>
6/7
Current number of RTSP
connections.
onlinenum_httppush
0,<positive
integer>
6/7
Current number of HTTP push server
connections.
onlinenum_sip
0,<positive
integer>
6/7
Current number of SIP connections.
eth_i0
<string>
1/7
Get network information from
mii-tool.
vi_i<0~(capability_nvi-1)>
<product dependent>
<boolean>
1/7
Virtual input
0 => Inactive
1 => Active
(capability_nvi > 0)
© 2019 VIVOTEK INC. All Right Reserved
40
7.2.1 Status per Channel
Group: status_c<0~(n-1)> for n channel products
n denotes the value of "capability_nvideoin"
NAME VALUE SECURITY
(get/set)
DESCRIPTION
signal_detect <boolean> 1/7 Indicates whether the video source is
connected or not.
* Only available when
capability_videoin_type is 0 or 1.
signal_type ntsc,pal 1/7 The actual modulation type.
* Only available when
capability_videoin_type is 0 or 1.
7.3 Digital Input Behavior Define
Group: di_i<0~(n-1)> for n is the value of "capability_ndi" (capability_capability_ndi > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
1/1 Indicates open circuit or closed circuit
(inactive status)
7.4 Digital Output Behavior Define
Group: do_i<0~(n-1)> for n is the value of "capability_ndo" (capability_ndo > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
normalstate open,
grounded
1/1 Indicate open circuit or closed circuit
(inactive status)