User Manual
Table Of Contents
- Overview
- Accessing the Network Camera
- Using VIVOTEK Recording Software
- Using 3GPP-compatible Mobile Devices
- Using RTSP Players
- Main Page
- Client Settings
- Configuration
- System > General settings
- System > Homepage layout
- System > Logs
- System > Parameters
- System > Maintenance
- Media > Image
- Media > Video
- Media > Video
- Media > Video
- Media > Audio
- Network > General settings
- Network > Streaming protocols
- Network > SNMP (Simple Network Management Protocol)
- Network > FTP
- Security > User accounts
- Security > HTTPS (Hypertext Transfer Protocol over SSL)
- Security > Access List
- PTZ > PTZ settings
- Event > Event settings
- Applications > Motion detection
- Applications > Smart VCA
- Applications > Tampering detection
- Applications > Audio detection
- Applications > Shock detection
- Applications > Package management - a.k.a., VADP (VIVOTEK Application Development Platform)
- Recording > Recording settings
- Local storage > SD card management
- Local storage > Content management
- Appendix
VIVOTEK
User's Manual - 327
© 2019 VIVOTEK INC. All Right Reserved
184
PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
trigger boot,
di,
pir,
motion,
seq,
recnotify,
tampering,
vi,
volalarm,
visignal,
vadp,
smartsd
<product
dependent>
6/6 Indicate the trigger condition:
"boot" = System boot.
"di"= Digital input.
"pir"= PIR detection.
"motion" = Video motion detection.
"seq" = Periodic condition.
"visignal" = Video input signal loss.
"recnotify" = Recording notification.
"tampering" = Tamper detection.
"vi"= Virtual input (Manual trigger).
"volalarm"= Audio detection.
"smartsd"= Lifetime detection of SD card.
"shockalarm" = Shock detection.
"virestore" = Video input signal restore.
"vadp" = VADP trigger.
* "smartsd" is only valid when smart SD
card is inserted
triggerstatus string[40] 6/6 The status for event trigger
di 0,<positive
integer>
6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input. The
LSB indicates DI 0.
* Only available when "capability_ndi" >
0
mdwin 0,<positive
integer>
6/6 Indicate the source window id of motion
detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0 0,<positive
integer>
6/6 Similar to mdwin. The parameter takes
effect when profile 1 of motion detection
is enabled.
© 2019 VIVOTEK INC. All Right Reserved
185
PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
vi 0,<positive
integer>
6/6 Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input. The
LSB indicates VI 0.
vadp
<product dependent>
0,<positive
integer>
6/6 Indicate the source id of vadp event
notification.
Each bi
t corresponds to one vadp source,
and the LSB indicates source id 0.
For example, to detect event from any
one of source id 0, 1 and 3, set vadp to
11.
* Only available when vadp is listed in
"capability_supporttriggertypes"
valevel 0,1 6/6 Select audio detection event.
0: not select
1: select
valevel0 0,1 6/6 Select audio detection profile event.
0: not select
1: select
inter 1~999 6/6 Interval of snapshots in minutes.
This field is used when trigger condition
is “seq”.
weekday 0~127 6/6 Indicate which weekday is scheduled.
One bit represents one weekday.
bit0 (LSB) = Saturday
bit1 = Friday
bit2 = Thursday
bit3 = Wednesday
bit4 = Tuesday
bit5 = Monday
bit6 = Sunday
For example, to detect events on Friday
and Sunday, set weekday as 66.
begintime hh:mm 6/6 Begin time of the weekly schedule.