User's Manual

Table Of Contents
VIVOTEK
User's Manual - 377
© 2020 VIVOTEK INC. All Right Reserved
228
NAME VALUE SECURITY
(get/set)
DESCRIPTION
capability_ptz_c<0~(
n-1)>_maxfocus
axisflip <boolean> 1/4 Custom home flip side.
returnhome
<boolean>
1/4
Enable/disable return home while
idle.
returnhomeinterval 1~999 1/4 While idle over this time interval,
idle action will be taken.
digitalzoom
<boolean>
1/4
Enable/disable digital zoom
idleaction_enable <boolean> 1/4 Enable/disable idle action while
idle
idleaction_type
pan,patrol,tour,home
,objtrack,prev
1/4
This field tells what kind of action
should be taken while idle.
idleaction_interval 1~999 1/4 While idle over this time interval,
idle action will be taken.
zoomenhance
<boolean>
1/4
Enable /disable zoom
enhancement
tour_index -1, 0~19 1/4 Index of the enabled tour group,
from 0 to 19.
Set -1 to disable all the tour
groups.
tour_i<0~19>_name
string[40]
1/4
Name of the tour.
tour_i<0~19>_type <boolean> 1/4 0 = Recorded tour
1 = Preset tour
tour_i<0~19>_speed
-5 ~ 5
1/4
Preset tour: pan and tilt speed
when moving between presets.
Recorded tour: unnecessary.
tour_i<0~19>_direction forward,backward,ra
ndom
1/4 User can choose which direction
the preset tour goes.
"forward": preset tour goes in
forward order.
"backward": preset tour goes in
backward order.
"random": the presets of the tour
will be recalled randomly.
* Only available when
"capability_presettourdirection"
© 2020 VIVOTEK INC. All Right Reserved
229
NAME VALUE SECURITY
(get/set)
DESCRIPTION
is 1.
* We support this parameter
when the version number
(httpversion) is equal or greater
than 0307a.
tour_i<0~19>_checklist string[512] 1/4 The indexes of preset positions,
separated by “,
tour_i<0~19>_dwelltim
e
string[512]
1/4
Preset tour: time to wait before
moving to the next preset
position, separated by “,
Recorded tour: number of
seconds to wait
before continuing a loop tour.
PLEASE REFER TO PTZ CONTROL API
7.43 UART Control
Group: uart (capability_nuart > 0 and capability_fisheye = 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40] 1/4 Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128]
1/4
Full path of the PTZ driver.
enablehttptunnel <boolean> 1/4 Enable HTTP tunnel channel to control
UA RT.
Group: uart_i<0~(n-1)> n is uart port count (capability_nuart > 0 and capability_fisheye = 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
baudrate
300,600,1200,2400,
4800,9600,19200,38
400,57600,115200
4/4
Set baud rate of COM port.
databit 5,6,7,8 4/4 Data bits in a character frame.