User's Manual
Table Of Contents
- Software Installation on page 10
- Overview
- VIVOTEK’s FE9380 and FE9382 are two H.265 fisheye fixed dome network cameras, both featuring a detailed 5-Megapixel CMOS sensor that produces superb image clarity. By employing H.265 compression technology and VIVOTEK’s Smart Stream III technology, these
- The cameras are both equipped with a removable IR-cut filter and WDR Pro technology, empowering the cameras to maintain optimal image quality around the clock and unparalleled visibility in high-contrast lighting environments. Moreover, the cameras are de
- * Depending on scene being monitored.
- Revision History
- Read Before Use
- Package Contents
- Symbols and Statements in this Document
- Physical Description
- LED Definition
- Hardware Installation
- Software Installation
- Network Deployment
- Accessing the Network Camera
- Using RTSP Players
- Using 3GPP-compatible Mobile Devices
- Using VIVOTEK Recording Software
- Main Page
- Client Settings
- Configuration
- System > General settings
- System > Homepage layout
- System > Logs
- System > Parameters
- System > Maintenance
- Media > Image
- Media > Video
- Media > Audio
- Media profiles
- Network > General settings
- Network > Streaming protocols
- Network > QoS (Quality of Service)
- Network > SNMP (Simple Network Management Protocol)
- Network > FTP
- Bonjour
- Security > User accounts
- Security > HTTPS (Hypertext Transfer Protocol over SSL)
- Security > Access List
- Security > IEEE 802.1x
- PTZ > PTZ settings
- Event > Event settings
- Applications > Motion detection
- Applications > Smart VCA
- Applications > DI and DO
- Applications > Tampering detection
- Applications > Audio detection
- Applications > Shock detection
- Applications > Package management - a.k.a., VADP (VIVOTEK Application Development Platform)
- Recording > Recording settings
- Storage
- Storage > SD card management
- Storage > NAS management
- Storage > Content management
- Appendix
VIVOTEK
378 - User's Manual
© 2020 VIVOTEK INC. All Right Reserved
230
NAME VALUE SECURITY
(get/set)
DESCRIPTION
paritybit
none,
odd,
even
4/4
For error checking.
stopbit 1,2 4/4 "1": One stop bit is transmitted to
indicate the end of a byte.
"2": Two stop bits are transmitted to
indicate the end of a byte.
If you want to transfer the stopbit for
150% of the normal time used to
transfer one bit, the
uart_i<0~(n-1)>_stopbit should be set
as 2 and the uart_i<0~(n-1)>_databit
set as 5 as well.
uartmode
rs485,
rs232
4/4
RS485 or RS232.
customdrvcmd_i<0~
9>
string[128] 1/4 PTZ command for custom camera.
* only available when
capability_camctrl_c0_rs485=2
speedlink_i<0~4>_n
ame
string[40]
1/4
Additional PTZ command name.
* only available when
capability_camctrl_c0_rs485=2
speedlink_i<0~4>_c
md
string[40] 1/4 Additional PTZ command list.
* only available when
capability_camctrl_c0_rs485=2
ptzdriver
0~19,
127 (custom),
128 (no driver)
1/4
The PTZ driver is used by this COM
port.
* only available when
capability_camctrl_c0_rs485=2
7.44 UART Control (SD Series)
Group: uart_i<0~(n-1)> n is uart port count (capability_nuart > 0 and the bit7 of
capability_ptzenabled is 0, the bit4 of capability_ptzenabled is 1)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
cameraid 1~255 4/4 Camera ID controlling external PTZ