User's Manual
Table Of Contents
- Software Installation on page 10
- Overview
- VIVOTEK’s FE9380 and FE9382 are two H.265 fisheye fixed dome network cameras, both featuring a detailed 5-Megapixel CMOS sensor that produces superb image clarity. By employing H.265 compression technology and VIVOTEK’s Smart Stream III technology, these
- The cameras are both equipped with a removable IR-cut filter and WDR Pro technology, empowering the cameras to maintain optimal image quality around the clock and unparalleled visibility in high-contrast lighting environments. Moreover, the cameras are de
- * Depending on scene being monitored.
- Revision History
- Read Before Use
- Package Contents
- Symbols and Statements in this Document
- Physical Description
- LED Definition
- Hardware Installation
- Software Installation
- Network Deployment
- Accessing the Network Camera
- Using RTSP Players
- Using 3GPP-compatible Mobile Devices
- Using VIVOTEK Recording Software
- Main Page
- Client Settings
- Configuration
- System > General settings
- System > Homepage layout
- System > Logs
- System > Parameters
- System > Maintenance
- Media > Image
- Media > Video
- Media > Audio
- Media profiles
- Network > General settings
- Network > Streaming protocols
- Network > QoS (Quality of Service)
- Network > SNMP (Simple Network Management Protocol)
- Network > FTP
- Bonjour
- Security > User accounts
- Security > HTTPS (Hypertext Transfer Protocol over SSL)
- Security > Access List
- Security > IEEE 802.1x
- PTZ > PTZ settings
- Event > Event settings
- Applications > Motion detection
- Applications > Smart VCA
- Applications > DI and DO
- Applications > Tampering detection
- Applications > Audio detection
- Applications > Shock detection
- Applications > Package management - a.k.a., VADP (VIVOTEK Application Development Platform)
- Recording > Recording settings
- Storage
- Storage > SD card management
- Storage > NAS management
- Storage > Content management
- Appendix
VIVOTEK
User's Manual - 379
© 2020 VIVOTEK INC. All Right Reserved
230
NAME VALUE SECURITY
(get/set)
DESCRIPTION
paritybit
none,
odd,
even
4/4
For error checking.
stopbit 1,2 4/4 "1": One stop bit is transmitted to
indicate the end of a byte.
"2": Two stop bits are transmitted to
indicate the end of a byte.
If you want to transfer the stopbit for
150% of the normal time used to
transfer one bit, the
uart_i<0~(n-1)>_stopbit should be set
as 2 and the uart_i<0~(n-1)>_databit
set as 5 as well.
uartmode
rs485,
rs232
4/4
RS485 or RS232.
customdrvcmd_i<0~
9>
string[128] 1/4 PTZ command for custom camera.
* only available when
capability_camctrl_c0_rs485=2
speedlink_i<0~4>_n
ame
string[40]
1/4
Additional PTZ command name.
* only available when
capability_camctrl_c0_rs485=2
speedlink_i<0~4>_c
md
string[40] 1/4 Additional PTZ command list.
* only available when
capability_camctrl_c0_rs485=2
ptzdriver
0~19,
127 (custom),
128 (no driver)
1/4
The PTZ driver is used by this COM
port.
* only available when
capability_camctrl_c0_rs485=2
7.44 UART Control (SD Series)
Group: uart_i<0~(n-1)> n is uart port count (capability_nuart > 0 and the bit7 of
capability_ptzenabled is 0, the bit4 of capability_ptzenabled is 1)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
cameraid 1~255 4/4 Camera ID controlling external PTZ
© 2020 VIVOTEK INC. All Right Reserved
231
NAME VALUE SECURITY
(get/set)
DESCRIPTION
camera.
Note:
Please set your speed dome to the
appropriate baud rate, and Camera ID,
e.g. 2400bps, camera ID 1,2,3,,,,etc.
All Camera IDs on the same controlling
system (NVR or rs485 keyboard) have to
be distinct.
Therefore, once you send a controlling
signal, each camera will only accept the
inputs with the corresponding ID.
baudrate 2400,4800,9600,19
200,38400,57600,1
15200
4/4 Set baud rate of COM port.
databit
5,6,7,8
4/4
Data bits in a character frame.
paritybit none,
odd,
even
4/4 For error checking.
stopbit 1,2 4/4 "1": One stop bit is transmitted to
indicate the end of a byte.
"2": Two stop bits are transmitted to
indicate the end of a byte.
If you want to transfer the stopbit for
150% of the normal time used to
transfer one bit, the
uart_i<0~(n-1)>_stopbit should be set
as 2 and the uart_i<0~(n-1)>_databit
set as 5 as well.
uartmode rs485 4/7 RS485 mode.
7.45 Lens Configuration
Group: lens for n channel products
n denotes the value of "capability_nvideoin"