User manual
VIVOTEK
User's Manual - 293  
8. Useful Functions 
8.1 Drive the Digital Output (capability.ndo > 0)
Note: This request requires Viewer privileges. 
Method: GET/POST 
Syntax: 
http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>] 
Where state is 0 or 1; “0” means inactive or normal state, while “1” means active or triggered state. 
PARAMETER  VALUE  DESCRIPTION 
do<num>  0, 1  0 – Inactive, normal state 
1 – Active, triggered state 
Example: Drive the digital output 1 to triggered state and redirect to an empty page. 
http://myserver/cgi-bin/dido/setdo.cgi?do1=1