User Manual
Table Of Contents
- Overview
- Accessing the Network Camera
- Using VIVOTEK Recording Software
- Using 3GPP-compatible Mobile Devices
- Using RTSP Players
- Main Page
- Client Settings
- Configuration
- System > General settings
- System > Homepage layout
- System > Logs
- System > Parameters
- System > Maintenance
- Media > Image
- Media > Video
- Media > Video
- Media > Audio
- Network > General settings
- Network > Streaming protocols
- Network > SNMP (Simple Network Management Protocol)
- Network > FTP
- Security > User accounts
- Security > HTTPS (Hypertext Transfer Protocol over SSL)
- Security > Access List
- PTZ > PTZ settings
- Event > Event settings
- Applications > Motion detection
- Applications > DI and DO
- Applications > Tampering detection
- Applications > Audio detection
- Applications > Package management - a.k.a., VADP (VIVOTEK Application Development Platform)
- Recording > Recording settings
- Local storage > SD card management
- Local storage > Content management
- Appendix
VIVOTEK
User's Manual - 327
stopbit 1,2 4/4 "1": One stop bit is transmitted to indicate the
end of a byte.
"2": Two stop bits are transmitted to indicate
the end of a byte.
If you want to transfer the stopbit for 150% of
the normal time used to transfer one bit, the
uart_i<0~(n-1)>_stopbit should be set as 2
and the uart_i<0~(n-1)>_databit set as 5 as
well.
uartmode rs485,
rs232
4/4 RS485 or RS232.
customdrvcmd_i<0~9> string[128] 1/4 PTZ command for custom camera.
speedlink_i<0~4>_name string[40] 1/4 Additional PTZ command name.
speedlink_i<0~4>_cmd string[40] 1/4 Additional PTZ command list.
ptzdriver 0~19,
127 (custom),
128 (no driver)
1/4 The PTZ driver is used by this COM port.
7.44 UART control (SD series)
Group: uart_i<0~(n-1)> n is uart port count (capability.nuart > 0 and the bit7 of capability_ptzenabled is 0, the
bit4 of capability_ptzenabled is 1)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
cameraid 1~255 4/4 Camera ID controlling external PTZ camera.
Note:
Please set your speed dome to the appropriate
baud rate, and Camera ID, e.g. 2400bps,
camera ID 1,2,3,,,,etc.
All Camera IDs on the same controlling system
(NVR or rs485 keyboard) have to be distinct.
Therefore, once you send a controlling signal,
each camera will only accept the inputs with
the corresponding ID.
baudrate 2400,4800,9600,19
200,38400,57600,1
15200
4/4 Set baud rate of COM port.
databit 5,6,7,8 4/4 Data bits in a character frame.