(n-1)>_focusmode"
uart 0 ~ "capability_nuart"-1 1/4 Select corresponding uart
(capability.nuart>0).
isptz 0 ~ 2 1/4 0: disable PTZ commands.
1: enable PTZ commands with PTZ
driver.
2: enable PTZ commands with UART
tunnel.
* Only available when bit7 of
capability_ptzenabled is 1
preset_i<0~(k-1)>_name string[40] 1/4 Name of the preset location.
preset_i<0~(k-1)>_zoom capability_ptz_c<0~(n-1)
>_minzoom ~
capability_ptz_c<0~(n-1)
>_maxzoom
1/4 Zoom position at each preset location.
preset_i<0~(k-1)>_focus capability_ptz_c<0~(n-1)
>_minfocus ~
capability_ptz_c<0~(n-1)
>_maxfocus
1/4 Focus position at each preset location.
preset_i<0~(k-1)>_
dwelling
0 ~ 999 1/4 The dwelling time of each preset
location
preset_i<0~(k-1)>_focus
setting
sync,
fixcurrent
1/4 The focus mode of each preset, which is
essential and should be grouped with
“preset_i<0~(k-1)>_name.
* We support this parameter when the
version number (httpversion) is equal or
greater than 0305b.
patrolseq string[120] 1/4 (For external device)
The indexes of patrol points, separated
by “,”
patroldwelling string[160] 1/4 (For external device)
The dwelling time of each patrol point,
separated by “,”
disablemdonptz <boolean> 1/4 Disable motion detection on PTZ
operation.
defaulthome <boolean> 1/4 This field tells system to use default
home position or not.
axisz capability_ptz_c<0~(n-1)
>_minzoom ~
capability_ptz_c<0~(n-1)
1/4 Custom home zoom position.