NETIO-230A FW 2.
User’s Manual NETIO-230A Contents CONTENTS ........................................................................................................................................... 1 WARNING ............................................................................................................................................. 3 1 INTRODUCTION ....................................................................................................................... 3 1.1 Features ....................
User’s Manual NETIO-230A 5.5 Troubleshooting ........................................................................................................................ 22 5.5.1 Reset to factory defaults ................................................................................................... 22 5.5.2 Fuse replacement .............................................................................................................. 22 6 LIABILITY ........................................................
User’s Manual NETIO-230A WARNING Unauthorized modification of this device can cause its damage or can cause injury! IMPORTANT NOTICE 1. 2. 3. 4. 1 The manufacturer is not responsible for possible damage caused by improper usage or usage in unsuitable environment. Device has been designed for indoor use only. Do not use the device during the strong vibrations. If your device won’t work properly, please contact your local reseller.
User’s Manual NETIO-230A 1.2 Specifications Input power: Max switched current: Latency: Operating temperature: 90 - 240 V AC 10 A max. 10 ms 0 – 70 °C 1.3 Minimum System Requirements Computer with installed Internet browser (Microsoft Internet Explorer, Opera, Mozilla Firefox, …) www.koukaam.
User’s Manual NETIO-230A 2 INTERFACE DESCRIPTION 2.1 Front View 1. 2. 3. 4. 5. Four LED indicators for actual status of each outlet. If the output is ON the LED indicator shines. RS-232C – Serial Port. Using the serial interface you can observe system logs or use Telnet for full device control. AUX – extension device interface. Two buttons for output manual control. (see chapter 5.4 for details) RJ-45 connector – network interface for connection to Ethernet / Internet. 2.2 Back View 1. 2. 3. 4.
User’s Manual NETIO-230A 3 INSTALLATION Before the first use please make sure that: 1. 2. Mains voltage is 90 – 230 V AC. Power cable is suitable for current up to 10A. 3.1 Hardware connection of the device 1. 2. 3. 4. Connect your NETIO-230A to the computer network (switch, router) using the Ethernet cable with RJ-45 connectors. Use cross cable when the device is directly connected to the PC. Connect the power cable to the device and then to power outlet.
User’s Manual NETIO-230A After you make requested changes based your network environment click Change IP. Utility will update settings of your NETIO and show device list with changed parameters. If there is DHCP server in your network and you are not willing to setup network parameters manually, just skip to the next step. Default IP address is 192.168.10.100 4. 5.
User’s Manual NETIO-230A 5 OPERATION AND SETTINGS 5.1 Output control and settings 5.1.1 Output control Click on Manual Control in the Menu on the left side. Output Manual control page will show up. NETIO-230A can control even all four outputs at the same time. Choose which ports should be turned ON/OFF and click Apply. If you would like only to restart the devices connected to the specific outputs, check Interrupt and then click Apply.
User’s Manual NETIO-230A 5.1.2 Output status and configuration Click on Status & configuration in the Menu on the left side. Output status and configuration page will show up. To setup specific output select it and press Modify. On the new page that will appear you can change detailed parameters of this specific output. www.koukaam.
User’s Manual NETIO-230A 5.1.2.1 Specific output configuration No.: Name: PON state: Manual control: Timer control: Timer mode: ON time: Output number (1 – 4) Output name Default output status after NETIO-230A power up – if you tick the checkbox, connected device will be turned ON after the NETIO starts or restarts. If you select this option it will be possible to control the output manually. If you select this option the output will be controlled automatically based on specified schedule.
User’s Manual OFF time: Week schedule: Interrupt delay (s): NETIO-230A Date and time to switch the output OFF. If you select the DAILY mode it is the date and time of the first execution. Select in which week days the Timer control should be in operation. Time in seconds for which the output should be turned OFF when the Interrupt function is used either in the manual mode or when the Watchdog feature is in operation. 5.1.2.
User’s Manual NETIO-230A 5.2 System configuration In this section the user can change network and e-mail parameters, system time, administrate user accounts or perform the firmware upgrade. 5.2.1 Network parameters Click Configuration link in the menu to change the system configuration. Insert network IP Address, Subnet Mask, Default Gateway (router address) and DNS Server regarding your network parameters.
User’s Manual NETIO-230A 5.2.2 E-mail configuration Click E-mail configuration in the menu to adjust e-mail settings. Please input sender (From), receiver (To) and a Message subject of the warning e-mail message. Also insert SMTP server address that will be used to send out the e-mail. You can check if e-mail setup is correct by pressing the Send test message button. Note: Current firmware version does not support SMTP authorization. www.koukaam.
User’s Manual NETIO-230A 5.2.3 Date and time settings Click Date & time in the menu to change the system date and time settings. NETIO-230A supports two methods of getting the right date and time values. It can be entered manually or obtained automatically from the SNTP server (this option is recommended if SNTP is available).
User’s Manual NETIO-230A 5.2.4 Manage users Device supports three levels of user access: Admin: User: Guest: Full administration. User which can control outputs, but cannot change any settings. Guest can only observe output status. You can also Add, Modify (password or user role) or Remove the user accounts. www.koukaam.
User’s Manual NETIO-230A 5.2.5 Firmware update Page Firmware Update is used to upload the new firmware into your NETIO-230A. After you click Firmware update link in the menu warning message will appear. Continue by clicking on the Update button. The device will then switch to a special firmware update mode. After approximately three seconds the Continue button will become active – click on it. Now insert the firmware file (xnetio.bin) and click the Update button.
User’s Manual NETIO-230A 5.3 Serial port, Telnet and CGI command control 5.3.1 Secure login NETIO-230A supports two login modes – open login and login with encrypted password. Encrypted password can be used for Telnet, http and serial link control. Login via web interface is encrypted automatically. For secure login you first need to obtain the hash code from the device. You can obtain this code in a return code after the connection via the RS-232 interface, via Telnet or CGI command hash.
User’s Manual NETIO-230A 5.3.4 List of commands for Telnet / serial link login User login with open password. Example: Using login admin admin you will login with username admin and password admin. clogin User login with encrypted password. version Shows current firmware version. alias Shows current device alias (your name for this device). quit Logout. reboot Logouts the current session and restarts the device.
User’s Manual NETIO-230A port setup
User’s Manual NETIO-230A system eth [ ] Setup of the network interface parameters – IP address, subnet mask and gate way parameters are needed to pass only if manual mode is entered. To allow changed values to take effect you must restart the device by typing the reboot command or turning it off and on again. Example: Command system eth manual 192.168.10.150 255.255.255.0 192.168.10.1 will set IP address 192.168.10.150, subnet mask 255.255.255.
User’s Manual NETIO-230A system update Switches the system to firmware upgrade mode. system reset to default Reverts all settings to factory default values. After issuing the command the device restarts automatically. 5.3.5 URL control using the CGI commands For some customers who already have their own web site or web control application, NETIO-230A can be easily integrated through convenient URLs. This section specifies the external HTTP based application programming interface.
User’s Manual NETIO-230A 5.4 Manual control Outputs could be also controlled manually using two buttons on the front panel. Keep the Select button pressed for three seconds. LED indicator in the right button will become lit – you have switched the device to manual control mode. Immediately after the device enters this mode you will hear a beep sound, which signalizes that the first output is now active. Press the ON/OFF button to switch its status.
User’s Manual NETIO-230A 6 LIABILITY The manufacturer cannot be held responsible for any technical or typographical errors and reserves the right to make changes to the product and manuals without prior notice. The manufacturer makes no warranty of any kind with regard to the material contained within this document, including, but not limited to, the implied warranties of merchantability and fitness for any particular purpose. © 2009 KOUKAAM a.s.