Quick Installation Guide

21
English
You can also create custom buttons on a web console, such as IR brightness (Lux),
threshold, dimming, etc. The camera default ID is 0. Make sure it is different from that of
the IR unit.
The IR control commands come in an 8 byte format. A sample command is shown below:
FF01
2101
bf00
05E7
FF01
Sync Addr Cmd1 Data1 Data2 Data3 Data4 Chks
1111 1111 0000 0001
FF012101bf0005E7
001000010000 0001 1011 1111 0000 0000 0000 0101 1110 0111
031
bitbit
The format uses Hexadecimal 0-9, A-F. Each 8-bit byte contains two 4-bit hexadecimal
characters. Two hexadecimal characters contained in each 8-bit eld of message.
If you need to cascade multiple IR units via the RS485 bus, please contact CaMate (http://
www.lidlight.com/) for a mobile app through which you can change device ID, baud rate,
and so on.
With a motorized IR unit, the IR light zoom control buttons will be available on the home
page of the camera web console. Click to change the IR lights angles. When IR lights
zoom in, the light beams become narrower, the farther the lights can reach. When zoomed
out, the wider the coverage, yet the range decreases.
Mechanical
IR Zoom functions
Use the zoom buttons to control the coverage of your IR lighting.