do_i<0~(ndo-1)> <boolean> 1/7 0 => Inactive, normal
1 => Active, triggered
(capability.ndo > 0)
onlinenum_rtsp integer 6/7 Current number of RTSP connections.
onlinenum_httppush integer 6/7
Current number of HTTP push server
connections.
eth_i0 <string> 1/7 Get network information from mii-tool.
vi_i<0~(nvi-1)> <boolean> 1/7 Virtual input
0 => Inactive
1 => Active
(capability.nvi > 0)
Digital input behavior define
Group: di_i<0~(ndi-1)> (capability.ndi > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
1/1
Indicates open circuit or closed circuit
(inactive status)
Digital output behavior define
Group: do_i<0~(ndo-1)> (capability.ndo > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
normalstate open,
grounded
1/1 Indicate open circuit or closed circuit
(inactive status)
Security
Group: security
NAME VALUE SECURITY
(get/set)
DESCRIPTION
privilege_do view, operator,
admin
6/6 Indicate which privileges and above can
control digital output
(capability.ndo > 0)
privilege_camctrl view, operator, 6/6 Indicate which privileges and above can