User Manual
VIVOTEK
User's Manual - 125
level
0~7
6/6
Levels used to distinguish the importance of
the information:
0: LOG_EMERG
1: LOG_ALERT
2: LOG_CRIT
3: LOG_ERR
4: LOG_WARNING
5: LOG_NOTICE
6: LOG_INFO
7: LOG_DEBUG
Camera PTZ control
Group: camctrl (capability.camctrl.httptunnel > 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
enablehttptunnel
<boolean>
4/4
Enable HTTP tunnel for camera control.
Group: camctrl_c<0~(n-1)> for n channel product (capability.ptzenabled)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
panspeed
-5 ~ 5
1/4
Pan speed
tiltspeed
-5 ~ 5
1/4
Tilt speed
zoomspeed
-5 ~ 5
1/4
Zoom speed
focusspeed
-5 ~ 5
1/4
Auto focus speed
preset_i<0~(npreset-
1)>_name
string[40]
1/4
Name of the preset location.
uart
0 ~ (m-1),
m is UART
count
1/4
Select corresponding uart
(capability.nuart>0).
cameraid
0~255
1/4
Camera ID controlling external PTZ camera.
hometype
<boolean>
1/4
The attribute defines whether the HOME
command emulation is enabled.
0: Use the preset position 0 as the home
position
1: Use HOME command (if the camera
supports it.)
isptz
0 ~ 2
1/4
0: disable PTZ commands.
1: enable PTZ commands with PTZ driver.
2: enable PTZ commands with UART tunnel.
disablemdonptz <boolean> 1/4 Disable motion detection on PTZ operation.
patrolseq string[120] 1/4 (For external device)
The indexes of patrol points, separated by ‚,‛
patroldwelling string[160] 1/4 (For external device)
The dwelling time of each patrol point,
separated by ‚,‛
UART control
Group: uart (capability.nuart > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40] 1/4 Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128] 1/4 Full path of the PTZ driver.
enablehttptunnel <boolean> 4/4 Enable HTTP tunnel channel to control
UART.
Group: uart_i<0~(n-1)> n is uart port count (capability.nuart > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
baudrate 110,300,600,12
00,2400,3600,
4800,7200,960
0,19200,38400,
57600,115200
4/4 Set baud rate of COM port.
databit 5,6,7,8 4/4 Data bits in a character frame.
paritybit none,
odd,
even
4/4 For error checking.
stopbit 1,2 4/4 1
2-1.5 , data bit is 5
2-2
uartmode rs485,
rs232
4/4 RS485 or RS232.
customdrvcmd_i<0~ string[128] 1/4 PTZ command for custom camera.