Hardware manual

TITAN SILICONSERVER HARDWARE MANUAL 17
Titan SiliconServer
Introducing the Titan SiliconServer
The server chassis is 4U (7”) high, 480 millimeters (19”) rack mountable and a maximum of 600
millimeters (22”) deep excluding the fascia. The server chassis consists of a passive backplane (which is
not removable), three hot swappable fan trays, and dual power supplies.
The pre-installed components perform functions essential to the integrity of the server. If there is an
issue with these components, replace them with the same component type. For more information, refer
to the Replacing Server Components section.
CAUTION: Each server power supply contains a lithium-ion battery that can only be serviced
by a BlueArc service engineer. The replacement battery must be of the same or
equivalent type recommended by the manufacturer. Dispose of any used batteries
in accordance with the manufacturer’s instructions.
Ventilation
On a Titan SiliconServer, there are vents and fan openings on the front and the rear. These openings
are designed to prevent the server from overheating.
Therefore, at least four inches of clearance must be present at the rear of the server rack so that
airflow is unrestricted.
CAUTION: Do not place the server in a built-in installation unless proper ventilation is
provided.
Do not operate the server in a cabinet whose internal ambient temperature
exceeds 40º C (104º F).