User's Guide

Appendix B: Error and Warning Codes
Possible BreadCrumb error and warning codes are listed below.
A BreadCrumb can have multiple errors or warnings listed in the Alerts tab of BC|Commander but only
one code will be flashed on the BreadCrumb’s status LED. A few codes such as 811 and 335 are non-flash-
ing alerts. For a BreadCrumb with other active alerts, the lowest number error code will flash on the
BreadCrumb’s status LED, and if there are no errors then the lowest number warning will flash.
Numeric error codes are flashed as groups of red (error) or yellow (warning) LED blinks. For example, a
meshed BreadCrumb displays a green LED. If the BreadCrumb starts to display warning 37, the following
would be seen: green (link state), yellow blinks 3 times, short pause, yellow blinks 7 times, long pause of
green (link state), yellow blinks 3 times, short pause, yellow blinks 7 times, etc.
Code Firmware Upgrade Codes (1*)
11 Flash image file does not exist.
12 Current flash image version is greater than versions of files found on USB drive.
13 No flash image files found.
14 Unable to mount USB drive.
15 Unable to retrieve next boot image number.
16 Continuous Transmit Mode
17 Unlocking of /dev/mtd0 failed.
18 fconfig for SetMainBoot failed.
19 Copying of zImage failed.
111 Copying of ramdisk failed.
112 FIS directory update of ramdisk failed.
113 Copying of etc failed.
114 FIS directory update of /etc failed.
115 Copying failed.
116 Flash unbundle failed.
117 Version information in flash file name and breadcrumb-buildinfo.conf do not match.
1171 Platform information in flash file name and breadcrumb-buildinfo.conf do not match.
118 Untar failed.
119 FIS directory update of kernel failed.
121 Failed to unmount /etc.
122 In Failsafe mode, but no USB drive detected.
123
BreadCrumb will be in failsafe mode and unable to communicate with other BreadCrumbs
after next reboot.
124 Failed to suspend bcconfigd.
125 Failed to set boot path to next image.
126 Failed to erase end of next file system image.