Service manual

Eccellenza Pod Replacing Components
63
Fuse Holder (15 Amp)
a. Disconnect the wiring from the fuse holder.
b. Loosen the plastic hex nut that secures the fuse holder to the
machine (see image).
c. Remove the fuse holder and replace it with the new one.
d. Transfer the fuse and the cap from the old fuse holder onto
the new one (if required).
e. Install the new fuse holder and secure it to the machine with
the hex nut.
f. Connect the wiring to the new fuse holder.
Service Cord
a. Disconnect the service cord wiring from the main power switch (switch tabs 1a
and 2a).
b. Disconnect the ground terminal from the grounding post on the metal wall.
c. Compress the strain relief and pull the service cord out of the opening in the
metal.
d. Install the strain relief onto the service cord and insert the end of the new
service cord through the opening in the metal.
e. Connect the service cord wiring to the main power switch (switch tabs 1a and 2a).
f. Connect the ground terminal to the grounding post on the metal wall.
g. Compress the strain relief and pull the service cord into of the opening in the
metal.