Installation guide
Chapter 4: Solution Implementation   
34 
EMC VSPEX End-User Computing: VMware Horizon View 5.3 
and VMware vSphere for up to 2,000 Virtual Desktops 
Implementation Guide 
Note: To determine the number of flash drives to use, refer to the Design 
Guide. 
c.  With Automatic selected, flash drives that will be used for creating FAST 
Cache are listed in the bottom portion of the dialog box. 
To select the drives manually, select Manual. 
d.  Click OK to create FAST Cache using the selected disks. 
Note: If a sufficient number of flash drives is not available, an error message 
appears and FAST Cache cannot be created. 
e.  Enable FAST Cache for the storage pool created for the solution. 
  After FAST Cache is created, it is enabled by default for all new pools 
created. 
  To enable FAST Cache for an existing pool, select the FAST Cache 
Enabled option under Advanced in the Storage Pool Properties dialog 
box. 
The FAST Cache feature on VNX does not cause an instant performance improvement. 
The system must collect data about access patterns and promote frequently used 
information into the cache. This process can take a few hours during which the 
performance of the array steadily improves. 
If the storage required for user data (that is, roaming user profiles or View Persona 
Management repositories and home directories) does not exist in the production 
environment already and the optional user data disk pack has been purchased, 
complete the following steps in Unisphere to configure two CIFS file systems on VNX: 
1.  Create a block-based RAID 6 storage pool with the characteristics shown in 
Table 10. 
  Create block-based RAID 6 storage pool Table 10.
Configuration 
Number of drives 
Drive type 
500 virtual desktops 
8 
2 TB NL-SAS 
1,000 virtual desktops 
16 
2 TB NL-SAS 
2,000 virtual desktops 
32 
2 TB NL-SAS 
The Design Guide describes the storage layouts. 
2.  Provision the required LUNs from the pool, as detailed in Table 11, to present 
to the Data Mover as dvols of a system-defined NAS pool. 
  Configure LUNs for NAS pool Table 11.
Configuration 
Number of LUNs 
LUN size (TB) 
500 virtual desktops 
10 
1 
1,000 virtual desktops 
10 
1.5 
Provision optional 
storage for user 
data 