Technical data
  Solution Technology Overview 
VMware Horizon View 5.3 and VMware vSphere for up to 2,000 Virtual 
Desktops Enabled by Brocade Network Fabrics, EMC VNX, and EMC Next-
Generation Backup 
41 
Figure 7.  Example of Highly-Available Brocade network design – for FC 
block storage network 
Brocade 6510 Fibre Channel switches supports provide high availabity for 
the VSPEX SAN infrastructure. Active – active links for all traffic from the 
virtualized to compute servers to the EMC VNX storage arrays. The 
Brocade
® 
6510 Switch meets the demands of hyper-scale, private cloud 
storage VSPEX storage traffic environments with market-leading Gen 5 
Fibre Channel technology and capability that supports the VSPEX 
virtualized architecture. 
The failure of a link in a route causes the network to reroute any traffic that 
was using that particular link—as long as an alternate path is available. 
Brocade Fabric Shortest Path First (FSPF) is a highly efficient routing 
algorithm that reroutes around failed links in less than a second. 
ISL Trunking improves on this concept by helping to prevent the loss of the 
route. A link failure merely reduces the available bandwidth of the logical 
ISL trunk. In other words, a failure does not completely “break the pipe,” 
but simply makes the pipe thinner. As a result, data traffic is much less likely 
to be affected by link failures, and the bandwidth automatically increases 
when the link is repaired. 










