User's Manual

1. Create a device profile in VoiceConsole.
2.
In the Advanced Device Settings text box, type this parameter: "distributable"="1"
The value of "1" marks the device profile as one that can be shared with other devices using the serial
connection between bays in the T5/A500 charger. If this parameter is not placed in the device profile
or if its value is set to zero, the device profile will not be shared.
3. Follow the instructions in the VoiceConsole online help for completing the device profile.
Note: The AC power indicator at the bottom right of the charger displays alternating green and
yellow lights when Easy Configuration operations are occurring. Devices should not be removed
until the individual indicator on the device blinks green or the charger's power indicator glows
solid green.
4. Use a serial cable to load this profile to a device.
Note: If the device profile you are loading is configured for use with static IP addresses, all the
devices will have the same IP address.
Easy Configuration: Bringing Additional Devices Online
A single device has been configured using the Easy Configuration Initial Setup instructions and
VoiceConsole Online Help. The following instructions are for configuring additional devices.
1. Place a properly configured T5, T5m, or A500 device in the transmit bay in the charger. When facing
the charger bay, the transmit bay is the first bay on the right. It is identified with an off-white latch.
The other bays have dark gray latches.
2. Place the new or repaired T5, T5m, or A500 devices in the remaining charger bays.
The LED indicators on the unconfigured devices flash green until the devices determine that they
cannot reach VoiceConsole.
The LED indicators flash orange as the devices attempt to connect to the network to listen for a
file broadcast.
The LED indicators flash green briefly as the devices receive profiles from the configured device
and verify the configuration.
The LED indicators change to solid red as the devices reboot.
When the devices have applied the configuration file and successfully contacted VoiceConsole, the
LED indicators change to blinking green. The devices are then ready to use or can be used in
another charger to bring additional devices online.
Note: The AC power indicator at the bottom right of the charger displays alternating green and
yellow lights when Easy Configuration operations are occurring. Devices should not be removed
until the individual indicator on the device blinks green or the charger's power indicator glows
solid green.
T5/A500 Combination Charger Power Supply Specifications
10-Bay Combination Charger Power Supply
Input Voltage: 100-250 Vac
Input Current: 2.4 A maximum
Input:
Line Frequency: 50-60 Hz
Output: 97.5 W (15 V x 6.5 A)Output:
Confidential: For informational use by Vocollect Resellers and customers only