Colonial™ High Efficiency Fireplace Insert EPA Certified (4.02grams/hr) Model TR004 Owners Manual (save this manual for future reference) This appliance meets U.S. Test Standard: UL 1482-2006 Do NOT use this appliance in a mobile home, Manufactured Home, trailer, or TENT – NO EXCEPTIONS! READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION of OR OPERATING this Appliance. Failure to follow instructions may result in property damage, bodily injury, or even death.
SAFETY INSTRUCTIONS Safety Notice: If this appliance is not properly installed a house/building fire may result. For your safety, contact local building or fire officials about permits, restrictions, and installation requirements for your area. Read All Instructions carefully. 1. The installation of this insert must comply with your local building code rulings. 2. Do not install this appliance in a mobile home, manufactured home, trailer or tent (NO EXCEPTIONS! per HUD Federal Standard: 24 CFR Ch.XX). 3.
SAFETY INSTRUCTIONS continued… 21. 22. 23. 24. 25. 26. 27. sons, especially young children should be alerted to the hazards from high surface temperatures. Keep away from a hot appliance to avoid burns or clothing ignition. CAUTION: Hot Surfaces. Keep children away. If small children will be in the same room as the appliance during operation, provide a sturdy barrier to keep them at a safe distance from the inser t.
Table of Contents Safety Precautions......................................................................................... 2 – 3 Product Dimensions............................................................................................ 5 Pre-installation Requirements............................................................................ 6 Chimney Condition ..................................................................................... 6 Minimum Clearances to Combustible Materials .........
Colonial™ dimensions TR004M | 11102010.
Pre-Installation Requirements Fireplace condition & Zero Clearance Requirements A masonry fireplace must meet minimum code requirements, National Fire Protection Association, (NFPA) 211, or the equivalent for a safe installation. Contact a professional, licensed installer, your local building inspector or the local fire authority for the requirements in your area. Your insurance company should be able to recommend a quallified inspector. Inspections should include the following: 1.
a. Existing fuel-fired equipment show evidence of back puffing, smoke roll-out, inefficient operation or excessive smell in the living area. b. Opening a window or door alleviates any of the above problems or symptoms. c. The building is constructed with a well-sealed vapor barrier, tight fitting windows or has powered exhaust fans. d. Excessive condensation on windows in the winter. e. The building has a ventilation system installed. f.
Assembly Instructions NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. Tools and Materials Required for Installation • • • • • • • • • tools Pencil 6 foot Folding Rule or Tape Measure Tin Snips Drill: Hand or Electric 1/8” dia.
panels, a top panel and a decorative trim frame. 11. Bolt the top panel (1) to the side panels (2) so the top surfaces are flush to one another. 12. Assemble the trim frame. The trim consists of a left (7) and right (4) side piece and a split top piece (left #6, right #5). These are joined by two corner connectors (8) and a straight center connector (9). These slide into the channel on the back of the frame and are secured with two set screws (10) in each piece. 15.
Chimney Specifications This appliance must be connected to a listed Stainless Steel Liner, that meets UL1777, which extends from the collar to the chimney cap according to the specifications listed on the previous pages. Chimneys perform two functions: 1). As a means of exhausting smoke and flue gases which are the result of fuel combustion. 2). The chimney provides “draft,” which allows oxygen to be continuously introduced into the appliance, so that proper combustion is possible.
Operating Instructions CAUTION: HOUSE FIRE HAZARDS This appliance is designed to burn WOOD FUEL ONLY! • Do not store wood on floor protector, underneath stovepipe(s) if applicable, or anywhere within minimum clearances from combustible surfaces specified for this appliance. Hardwood, 17” to 19”, should be split and air dried (seasoned) for 6 months to obtain maximum burning efficiency. Wood should be stored in a dry, well ventilated area. • Overfiring may cause a house fire.
Operating Instructions continued . . . secondary flames then slowly reset the air control to the desired setting. Initially it may take several attempts to figure your insert out. But once you find the operating “sweet spot” and the correct mix of procedures to get there, only minor adjustments will be necessary. The best indicator of a properly operating insert is to look for smoke coming out of the chimney. You may see steam emissions that will quickly dissipate.
Operating continued . . . Chimney Maintenance Blower Operation Preventing Creosote Buildup The variable speed blower circulates air warmed by the firebox into the living area to distribute the heat more evenly. The blower control knob is located on the side of the blower housing. Turn the knob clockwise to turn the blower on. The speed is controlled by turning the knob clockwise for slower speeds and counter-clockwise for faster speeds.
Service Hints house or tree falls on top of the chimney like water over a dam, beating down the smoke. The top of the chimney should be at least three (3) feet above the roof and be at least two (2) feet higher than any point of the roof within ten (10) feet. Glass Care The following usage and safety tips should be observed: 1. Inspect the glass regularly for cracks and breaks. If you detect a crack or break, extinguish the fire immediately and contact the manufacturer for a replacement. 2.
Parts - TR004 Colonian High-Efficiency Insert When ordering missing or replacement parts, always give the Model Number of the insert, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. Ref. No. Qty. 01 02 03 04 05 06 07 08 09 10 11 12 13 – – – – – 14 15 16 17 18 19 20 21 22 23 34 TR004M | 11102010.0 Part No.
Parts - TR004 Colonial High-Efficiency Insert When ordering missing or replacement parts, always give the Model Number of the insert, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. 33 30 31 24, 25, 26 27 28 29 32 Ref. No. 24 25 26 27 28 29 30 31 32 33 Part No. Description Qty. 04-24 Door Assembly (complete)..................... 1 04-25 Handle Assembly (complete).............. 1 04-26 Door Frame (only)......
Floor Protector Material Calculations This stove has been tested for and must be installed on a floor protector with the proper Thermal Resistance or R-value as stated in the installation instructions on page 3, “Locating Stove” step 1, of this manual. If the floor protector materials listed in the instructions are not available, materials with an equivalent R-value may be substituted.
This Vogelzang heating appliance is safe when installed properly and will provide you with years of service. However, always exercise good judgement when you are using this stove. You are dealing with FIRE! Fire is inherently dangerous and must be treated with respect.