DELUXE BOXWOOD STOVE Model BX42E Owners Manual (save this manual for future reference) READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS STOVE. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. REFER TO MARKINGS ON STOVE LABELS FOR ADDITIONAL INFORMATION. NOTE: THIS STOVE IS NOT A UL LISTED STOVE. NOTE: IT IS RECOMMENDED INSTALLATION BE COMPLETED BY A QUALIFIED HEATING EQUIPMENT INSTALLER! DO NOT INSTALL IN A MOBILE HOME.
SAFETY INSTRUCTIONS Read All Instructions carefully. 1. The installation of this stove must comply with your local building code rulings. Please observe the clearances to combustibles (see reference figures 7–9). Do not place fuel, furniture or any other objects within the clearance area. 2. Verify that the stove is properly installed before firing the stove for the first time.
SAFETY INSTRUCTIONS continued… 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. ceptible domestic pets (such as birds) should take prudent precautions. Open windows and doors as needed to clear smoke and/or odor. Paint discoloration will occur if the stove is over fired. This stove has a painted surface which is durable but it will not stand rough handling or abuse. When installing your stove, use care in handling. Clean exterior with soap and warm water when stove is not hot.
TABLE OF CONTENTS Safety Precautions......................................................................................... 2 – 3 Tools and Materials Required for Installation.................................................... 5 Assembly Instructions ........................................................................................ 5 Locating the Stove .............................................................................................. 6 Floor Protector, Minimum Clearances ...............
ASSEMBLY INSTRUCTIONS NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. tools required Safety Glasses Hearth Gloves Pencil 6 foot Folding Rule or Tape Measure Tin Snips Drill: Hand or Electric materials required 1/8” dia.
ASSEMBLY INSTRUCTIONS continued… LOCATING STOVE Proper clearances must be maintained for adequate air circulation and protection from radiant heat. Adequate ventilation must be provided while operating this stove. 1. The stove must be placed on solid concrete, solid masonry, or when installed on a combustible floor, on a Type 2 floor protector listed to standard UL 1618 with a minimum R value of 3.0 and a minimum thickness of 1” or equivalent.
LOCATING STOVE continued… sections together. DO NOT connect this stove to any air distribution or duct system. 5. R e c h e c k c l e a r a n c e s f r o m t h e s t o v e , connector stove pipe, and corner clearances using the illustrations (figure 6–8) and your local building codes or fire protection ordinances. NOTE: ANY WALL CONTAINING COMBUSTIBLE MATERIAL SUCH AS WOODEN STUDS OR DRYWALL AND FACED WITH BRICK OR STONE MUST BE CONSIDERED A COMBUSTIBLE SURFACE. 6.
CONNECTOR PIPE INSTALLATION NOTE: CONNECTOR PIPE IS NOT INCLUDED. TO PURCHASE, VISIT YOUR LOCAL HARDWARE, HOME, OR BUILDING CENTER. SEE “LOCATING STOVE” PAGE 6 & 7 FOR ADDITIONAL SPECIFICATIONS. Connector pipe is used to make the connection from the final positioning of your stove to an approved chimney. Connector pipe is NOT included as part of the stove. Connector pipe must be 6˝/152mm diameter minimum of 24 MSG (minimum standard gauge) black or 26 MSG blue steel stove pipe.
CHIMNEY CONNECTIONS The stove must be connected to either a lined masonry or manufactured metal chimney built and tested to the specifications listed on the previous pages. Chimneys perform two functions: 1). As a means of exhausting smoke and flue gases which are the result of fuel combustion. 2). The chimney (only) provides “draft” which allows oxygen to be continuously introduced into the appliance, so that proper combustion is possible. This stove relies on natural draft to operate.
CHIMNEY CONNECTIONS continued … MANUFACTURED CHIMNEY REFER TO CHIMNEY AND CHIMNEY CONNECTOR MAKER’S INSTRUCTIONS FOR INSTALLATION AND USE. Figure 12 - Chimney Construction Through Roof Chimney Minimum Height Requirements: (1) Overall Height – 11 ft./3.35m min. (2) Height above roof – 3 ft./91cm (3) Height above slope – 2 ft./61cm min. within 10 ft./3.05m (4) Minimum rise before horiz. section – 24 in./61cm NOTICE: If minimum chimney requirements are not met, your stove will not operate properly.
CHIMNEY CONNECTIONS continued … enough insulation and/or air cooling on the base, back and sides so they can be safely installed in direct contact with combustible floors and walls. Although many prefabricated fireplaces carry endorsements from nationally recognized organizations for use as fireplaces, they have not been tested for connection to wood stove heaters. Connecting a stove to such a device will void the manufacturer’s warranty.
OPERATING INSTRUCTIONS CAUTION: HOUSE FIRE HAZARDS • DO NOT STORE WOOD ON FLOOR PROTECTOR, UNDERNEATH STOVEPIPE, OR ANYWHERE WITHIN MINIMUM CLEARANCES FROM COMBUSTIBLE SURFACES SPECIFIED FOR THIS STOVE. • OVER FIRING MAY CAUSE A HOUSE FIRE. YOU ARE OVER FIRING IF A UNIT OR CHIMNEY CONNECTOR GLOWS RED. OPERATING SAFETY PRECAUTIONS 1. NEVER OVER FIRE THIS STOVE BY BUILDING EXCESSIVELY HOT FIRES AS A HOUSE/ BUILDING FIRE MAY RESULT.
OPERATING INSTRUCTIONS continued … NOTICE - INITIAL BURNS to Cure PAINT Because of the high operating temperatures, this stove uses a special high-temp paint which requires a series of burns to cure the paint for durability and a lifetime of service. Proper curing of the high-temp paint requires a series of three initial burns. The stove should be allowed to cool off between each burn. The first two burns should be small fires and low temperatures (250°F/120°C) for a duration of 20 minutes each.
MAINTENANCE & SERVICE continued … Preventing Creosote Buildup 1. Creosote will inevitably form in your chimney and connector pipe. Following these steps will help reduce the rate of build up. 2. BURN ONLY SEASONED WOOD that has dried for at least one year. (<20% humidity by weight) 3. Burn hardwood rather than softwood. Hardwood is denser or heavier wood and burns hotter. 4. Do not attempt to burn (or mix in) green or wet wood. The use of green or wet wood will cause a rapid build up of creosote.
ORDERING PARTS - BX42E BOXWOOD STOVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. Part No. 42-01 42-02 42-03 42-04 42-05 42-06 42-07 42-08 42-09 42-10 42-11 42-12 42-13 42-14 42-15 42-16 42-17 42-18 42-19 HP-42 Description Qty. Leg.......................................................
FLOOR PROTECTOR MATERIAL CALCULATIONS This stove has been tested for and must be installed on a floor protector with the proper Thermal Resistance or R-value as stated in the installation instructions on page 3, “Locating Stove” step 1, of this manual. If the floor protector materials listed in the instructions are not available, materials with an equivalent R-value may be substituted.
CHIMNEY CONNECTOR SYSTEMS & CLEARANCES A. Brick Masonry Minimum 3.5˝/ 89mm thick brick masonry all framed into combustible wall with a minimum of 12˝/305mm brick separation from clay liner to combustibles. The fireclay liner shall run from outer surface of brick wall to, but not beyond, the inner surface of chimney flue liner and shall be firmly cemented in place. B. Insulated Sleeve Solid-insulated, listed factory-built chimney length of the same inside diameter as the chimney connector and having 1˝/25.
This Vogelzang heating appliance is safe when installed properly and will provide you with years of service. However, always exercise good judgement when you are using this stove. You are dealing with FIRE! Fire is inherently dangerous and must be treated with respect.