PONDEROSA™ HIGH-EFFICIENCY WOODSTOVE EPA Certified (3.20 grams/hr.) Model TR007 Owners Manual (Save These Instructions) Le manuel de langue français est disponible à www.vogelzang.com French language manual is available at www.vogelzang.com Report No. 180-S-09-2 READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS STOVE. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. REFER TO MARKINGS ON STOVE LABELS FOR ADDITIONAL INFORMATION.
SAFETY INSTRUCTIONS-Read All Instructions Carefully. 1. The installation of this stove must comply with your local building code rulings. Please observe the clearances to combustibles (see reference figures 5–7). Do not place fuel, furniture or any other objects within the clearance area. 2. Verify that the stove is properly assembled and installed before firing the stove for the first time.
SAFETY INSTRUCTIONS continued… 18. During the first 12 to 15 fires the special paints and protective oils used in construction of your stove may give off some smoke and odor while they are curing. This should disappear after a short period of time and not occur again. Persons with lung conditions or owners of susceptible domestic pets (such as birds) should take prudent precautions. Open windows and doors as needed to clear smoke and/or odor. Paint discoloration will occur if the stove is over fired. 19.
TABLE OF CONTENTS SAFETY PRECAUTIONS................................................................................ 2 – 3 TOOLS AND MATERIALS REQUIRED FOR INSTALLATION............................. 5 ASSEMBLY INSTRUCTIONS ............................................................................... 5 LOCATING THE STOVE ....................................................................................... 7 Floor Protector, Minimum Clearances ...............................................
ASSEMBLY INSTRUCTIONS NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. TOOLS AND MATERIALS REQUIRED FOR INSTALLATION 2. Stove may be lightened for positioning by removing fire brick. Note position and arrangement of bricks. Firebrick, Ash Drawer & Ash Cover MUST be replaced before use. DO NOT USE with missing or cracked fire brick.
ASSEMBLY INSTRUCTIONS . . . continued aligning the fan opening to the opening in the back of the stove. Secure with four sheet metal screws. 4. After assembly, check to make sure fire brick are properly positioned and ash clean out cover is in place. 5. Route the power cord away from stove. Do not allow the power cord to touch any hot surfaces. Keep power cord at least 12˝ from stove surfaces. 6. Once stove is positioned, plug power cord into a grounded 120v outlet. LOCATING STOVE 1.
LOCATING STOVE . . . continued CLEARANCES | TOP VIEW COMBUSTIBLE CONSTRUCTION IN ACCORDANCE WITH US NFPA 211 17"/ 43.2cm min BACKWALL DASHED LINES SHOW HORIZONTAL CHIMNEY CONNECTOR AND ADDITIONAL FLOOR PROTECTOR REQUIRED BENEATH AND EXTENDING 2"/50.8mm BEYOND 40"/ EACH SIDE OF CONNECTOR PIPE 102cm 8"/21cm min. 56"/142.3cm 30"/76.2cm SIDEWALL 26"/66.1cm min. FLOOR PROTECTOR 24"/61cm Minimum Clearances for installation according to UL 1482 (US) & ULC-S627 (CDN) 18"/46cm min. 8"/21cm min. Figure.
LOCATING STOVE . . .
CONNECTOR PIPE INSTALLATION NOTE: CONNECTOR PIPE IS NOT INCLUDED. TO PURCHASE, VISIT YOUR LOCAL HARDWARE, HOME, OR BUILDING CENTER. SEE “LOCATING STOVE” PAGE 6 FOR ADDITIONAL SPECIFICATIONS. Connector pipe is used to make the connection from the final positioning of your stove to an approved chimney. Connector pipe is NOT included as part of the stove. Connector pipe must be 6”/152mm diameter minimum of 24 MSG (minimum standard gauge) black or 26 MSG blue steel stove pipe.
MOBILE HOME INSTALLATION INSTRUCTIONS This stove is approved for mobile home installation in the USA only (DO NOT INSTALL IN MOBILE HOMES IN CANADA). In addition to the installation and safety instructions, the following requirements are MANDATORY for installation in a mobile home. All mobile home installations must be made in accordance to Manufactured Home and Safety Standard (HUD), CFR 3280, part 24. 1. The stove must be permanently bolted to the floor to prevent movement of the stove.
CHIMNEY CONNECTIONS The stove must be connected to either a lined masonry or manufactured metal chimney built and tested to the specifications listed on the previous pages. Chimneys perform two functions: 1). As a means of exhausting smoke and flue gases which are the result of fuel combustion. 2). The chimney (only) provides “draft” which allows oxygen to be continuously introduced into the appliance, so that proper combustion is possible. This stove relies on natural draft to operate.
CHIMNEY CONNECTIONS continued … MANUFACTURED CHIMNEY REFER TO CHIMNEY AND CHIMNEY CONNECTOR MAKER’S INSTRUCTIONS FOR INSTALLATION AND USE. Use only 6˝/152mm diameter manufactured chimney system listed to UL 103 HT (US) or ULC-S629 (CDN). Chimney made to this listing is High Temperature rated to 2100°F/1149°C. Use chimney from only one manufacturer. Never mix brands. Carefully follow the chimney manufacturer’s stated requirements and clearances.
CHIMNEY CONNECTIONS continued … tified Chimney Sweep, or a knowledgeable inspector. Consult your insurance company if you cannot find a qualified expert. CAUTION: NOT ALL FIREPLACE CHIMNEYS ARE SUITABLE FOR CONVERSION TO ACCOMMODATE CONNECTION TO A WOOD STOVE. CHECK WITH A QUALIFIED EXPERT. 8˝/203mm of liner must remain below the entry position.
CHIMNEY CONNECTOR SYSTEMS & CLEARANCES NFPA 211 (US) NOTE: In Canada, installation must conform to CAN/CSA-B365 when passing through combustible construction. A. Brick Masonry Minimum 3.5˝/89mm thick brick masonry all framed into combustible wall with a minimum of 12˝/305mm brick separation from clay liner to combustibles. The fireclay liner shall run from outer surface of brick wall to, but not beyond, the inner surface of chimney flue liner and shall be firmly cemented in place. B.
OPERATING INSTRUCTIONS CAUTION: HOUSE FIRE HAZARDS • DO NOT STORE WOOD ON FLOOR PROTECTOR, UNDERNEATH STOVEPIPE, OR ANYWHERE WITHIN MINIMUM CLEARANCES FROM COMBUSTIBLE SURFACES SPECIFIED FOR THIS STOVE. • OVER FIRING MAY CAUSE A HOUSE FIRE. YOU ARE OVER FIRING IF A UNIT OR CHIMNEY CONNECTOR GLOWS RED. OPERATING SAFETY PRECAUTIONS 1. NEVER OVER FIRE THIS STOVE BY BUILDING EXCESSIVELY HOT FIRES AS A HOUSE/ BUILDING FIRE MAY RESULT.
OPERATING INSTRUCTIONS continued . . . height, weather, log size, wood species and moisture content. Some experimentation will initially be required to find that “sweet spot” where your stove performs best. The following will give you a starting point to find your optimum settings. When first loading fuel set the primary air inlet control (center) at the wide open (push in) position for at least 15–20 minutes (the high burn duct control should be closed – pulled out – when starting fires).
make sure to clear them away from the Lower Primary Air Orifice (LPAO) and rake a slight (1˝ – 2˝/25mm-50mm wide) trough down the center of the coal bed from front to back prior to loading the fuel. 8. Once fuel has been loaded, close the door and leave the air inlet control fully open until fire is well established (at least 15–20 minutes) being careful not to over fire (if any of the exterior parts of the stove or chimney connections begin to glow you are over firing the stove). 9.
OPERATING continued . . . removed using a chimney brush or other commonly available materials from your local hardware retailer. Chimney fires burn very hot. If the unit or chimney connector should glow red, reduce the fire by closing the inlet air control and immediately call the fire department. CAUTION: A CHIMNEY FIRE MAY CAUSE IGNITION OF WALL STUDS OR RAFTERS WHICH WERE ASSUMED TO BE A SAFE DISTANCE FROM THE CHIMNEY.
SERVICE HINTS continued . . . 1. Atmospheric Pressure and Air Supply Atmospheric pressure that affects the draft may occur from outside the structure, inside the structure, or both. High pressure weather (clear and cold) usually produces a better chimney draft than low pressure (overcast and damp) conditions. Negative pressure can be created inside a home by appliances that expel air from within such as bathroom vents, range hoods, clothes dryers, and forced air furnaces.
SERVICE HINTS continued . . . GLASS REPLACEMENT WARNING: REPLACE GLASS ONLY WITH 5MM HIGH TEMPERATURE CERAMIC GLASS OF THE PROPER SIZE. DO NOT USE SUBSTITUTE MATERIALS SUCH AS TEMPERED GLASS OR DOUBLE THICKNESS WINDOW GLASS! CONTACT THE STOVE MANUFACTURER FOR REPLACEMENT GLASS. Gasket and Glass cleaning products are available at local retail home centers. Manufacturers of cleaning products include, A.W. Perkins Co. (www.awperkins. com) or Rutland Products (www.rutland.com).
WIRING DIAGRAM - MODEL F-6 BLOWER OPTION DANGER: SHOCK HAZARD. DISCONNECT POWER SOURCE BEFORE INSTALLATION AND WHENEVER SERVICING BLOWER ASSEMBLY. CAUTION: MOVING PARTS CAN CAUSE INJURY. DO NOT OPERATE WITH COVER REMOVED. NOTICE: ANY REPLACEMENT WIRING MUST HAVE E Q U I VA L E N T I N S U L A TION AND TEMPERATURE RATING (105°C). VGZ-031 / 20120619.1 www.vogelzang.
ORDERING PARTS - TR007 PONDEROSA™ STOVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. NOTE: F6 Blower is Optional Equipment Ref. No. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 Part No.
ORDERING PARTS - TR007 PONDEROSA™ STOVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. 11 38 39 36 35 WG-01 Ref. No. 11 33 34 37 Part No. Description Qty. 07-11 Hinge Pin............................................. 2 07-33 Door Assembly (complete).....................
FLOOR PROTECTOR MATERIAL CALCULATIONS This stove has been tested for and must be installed on a floor protector with the proper Thermal Resistance or R-value as stated in step 1 of the installation instructions under “Locating Stove” section of this manual. If the floor protector materials listed in the instructions are not available, materials with an equivalent R-value may be substituted.
CHIMNEY & STOVE MAINTENANCE LOG DATE OF SERVICE VGZ-031 / 20120619.1 PERFORMED BY DESCRIPTION www.vogelzang.
This Vogelzang heating appliance is safe when installed properly and will provide you with years of service. However, always exercise good judgement when you are using this stove. You are dealing with FIRE! Fire is inherently dangerous and must be treated with respect. Stay warm and in good health! Respectfully yours, Steve Vogelzang Proprietor THIS STOVE MAY BE INSTALLED IN A MOBILE HOME WITH SPECIFIC INSTALLATION INSTRUCTIONS FOR SUCH USE. SEE PAGE 10.