Datasheet
creating connections
creating connections
www.vogtshop.ch
Wire
Applicable
wire
standard
Material
Package
quantity
Rating
Tool
For saftey use, please read following points prior to usage.
• Check the product speciaction.
• For copper wire only.
• Do not use other wires than applicable wires per standard.
• Use within the rated voltage, current, temperature range and assemble
temperature.
• Connection of wire and connector shall be made when power is turned o.
• Indoor use only.
• Avoid using under conditions such as high temperature, low temperature,
high humidity, much dust, places with vibration and strong impact, water,
oils, chemicals and corrosive gas.
• Fix wires without causing tension.
• IDC contact is not reusable
• Straight connection in and out.
pull of straight
Dimension a: Befor IDC 8.1, after IDC 5.8
Technical
specications
Wire entrance
Dimension in mm
Wire size
0.2mm
2
- 0.5mm
2
2.1mm
Max. wire outside diameter
UL1007 AWG24-AWG20
KV (per JIS) 0.2mm
2
- 0.5mm
2
KIV (per JIS) 0.3mm
2
VFS (JIS) 0.3mm
2
Plier
Voltage
Current
Temperature range
Assemble temperature
100V
2A (0.2mm
2
)
3A (0.5mm
2
)
-20°C to +75°C
0°C to +40°C
Housing
Cover
Contact
Connecting plate
Polycarbonate (black)
Polycarbonate (yellow and translucent)
Pre-tin plated bronze
Polycarbonate (white)
Connector 3924n
Connecting plate 3924n.1
100 pcs.
50 pcs.
RoHS compliant