A-8 QX Hawk Industrial Imager User’s Manual
Electrical Specifications
Appendix B — Electrical Specifications
QX Hawk Connectors
Power Requirement
9 Watts (max.), 5-28VDC, 200 mV p-p max. ripple, 270mA at
24VDC (typ.)
Ground
Output 3
Output 1
Output 2
New Master
Default
Power
Input Common
Output Common
RS-232 RxD
Trigger
RS-232
TxD
QX Hawk (Back View)
Input
Common
RS-422/485 RxD (–)
RS-232 TxD/
RS-232 RTS
Trigger
RS-232 RxD/
RS-232 CTS
Power
Ground
RS-422/485
RxD (+)
RS-422/485
TxD (+)
RS-422/485 TxD (–)
Input 1
Termi nat ed
A (Serial) M12 12-pin Plug
B (Serial) M12 12-pin Socket
A is a serial M12 12-pin plug.
B is a serial M12 12-pin socket or an Ethernet M12
8-pin socket.
TX (+)
RX (–)
RX (+)
TX (–)
Terminated
Terminated
B (Ethernet) M12 8-pin Socket
Term ina ted
Termi nat ed